OSHRC Commission decision Docket 93-0596, 93-0597, 93-0614 Decided June 27, 1995 Settled

Ingalls Shipbuilding, Inc.

Consolidated citations settle for $8,850

Apply this precedent to your situation

This is citable Commission precedent from 1995, and it may have been appealed since. Ezel checks how it stands today and answers your situation, with citations.

Currency note: this decision dates from 1995
The OSHA standards may have been amended, penalty amounts have been adjusted, and later Commission or court decisions may have changed the analysis since then. Treat this page as historical context, not current compliance advice. Verify the current standard before relying on any specific rule, threshold, or penalty mentioned here.
Decision of the Commission
This is a decision of the Occupational Safety and Health Review Commission, the highest level of agency review, citable as Commission precedent. It may have been appealed to a U.S. Court of Appeals after issuance; check subsequent history before relying on it. The full text below is from the official OSHRC release.
About this page: The plain-English summary and decision snapshot below were written by Ezel based on the official OSHRC release. The full text is the Commission's own document.
Read the official release (oshrc.gov)

Plain-English summary

The Commission approved a complete settlement of three consolidated Ingalls Shipbuilding, Inc. dockets. Seven electrical-panel cabinet items were reclassified as other-than-serious with $600 total penalties, and Ingalls agreed to keep panel doors closed and replace missing blanks. A surface-supplied diving item was reduced to $4,000, with an agreement to station a scuba-equipped diver able to communicate with the air-hose attendant during work in physically confining spaces. One electrical item was withdrawn, while another was reduced to $1,750 and paired with a mandatory protective-equipment rule and progressive discipline. A paint-ventilation item was amended to $2,500, with commitments to maintain vapor concentrations below ten percent of the lower explosive limit and conduct frequent monitoring. Ingalls withdrew its contests and agreed to pay $8,850 total, and the Commission made the settlement its final order.

Decision snapshot

  • Cited standard(s): 29 C.F.R. §§ 1910.303(g)(2)(i), 1910.425(c)(2), 1915.181(b), 1915.335(a)(1)(i), and 1915.36(a)(4).
  • Outcome: Settled. The consolidated citation items were withdrawn, reclassified, or amended under a settlement requiring $8,850 in total penalties and specified abatement measures.
  • Key point: The settlement paired reduced and reclassified penalties with concrete controls for electrical panels, confined-space diving, electrical protective equipment, and flammable paint vapors.

Full text (OSHRC public release)

                                 United States of America
           OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION
                            1120 20th Street, N.W., Ninth Floor
                               Washington, DC 20036-34 19
                                                                               Phone: (202) 606-5400
                                                                                 Fax: (202) 606-5050




                                                  .
                                                  .

SECRETARY OF LABOR, ..

                  Complainant,

          v.                                                OSHRC Docket Nos. 93-596,
                                                            93-597 & 93-614 (Consolidated)

INGALLS SHIPBUILDING, INC.,

                  Respondent,
                                                  .
                                                  .

INTERNATIONAL BROTHERHOOD ..
OF ELECTRICAL WORKERS, ..
LOCAL NO. 773, ..

          and
                                                  .

PASCAGOULA METAL TRADES COUNCIL, I
AFL-CIO, ..

                  Authorized Employee
                  Representatives.
                                                  .
                                                  .
                                                  .




                                        ORDER

    This matter is before the Commission on a direction for review entered by Commissioner

Edwin G. Foulke, Jr. on December 28, 1994. The parties have now filed a stipulation and
settlement agreement.

    The Commission has reviewed the record, and based upon the representations appearing

in the stipulation and settlement agreement, the Commission concludes that this case raises no
matters warranting further review. The terms of the stipulation and settlement agreement do not
appear to be contrary to the purposes of the Occupational Safety and Health Act and are in
compliance with the Commission’s Rules of Procedure.
Accordingly, the Commission incorporates the terms of the stipulation and settlement
agreement into this order, and we set aside the Administrative Law Judge’s decision and order
to the extent that it is inconsistent with the stipulation and settlement agreement. This is the final
order of the Commission in this case. See 29 U.S.C. 08 659(c), 660(a), and (b).

                                                   BY DIRECTION OF THE COMMISSION




                                                   Executive Secretary
   I certify that a copy of this order has been served on the following persons this 27th day

of June 1995:

Daniel J. Mick
Orlando J. Pannocchia
Office of the Solicitor, U.S. DOL
Room S4004
200 Constitution Ave., N.W.
Washington, D.C. 20210

Cynthia Welch Brown
Office of the Solicitor, U.S. DOL
Chambers Bldg, Highpoint Office Center
Suite 150, 100 Centerview Drive
Birmingham, AL 35216

Robert J. Ariatti, Jr.
Ingalls Shipbuilding, Inc.
P. 0. Box 149
Pascagoula, MS 39568-1049

W. D. McGill
Business Manager, I.B.E.W.
Local 733
P. 0. Box 1247
Pascagoula, MS 39568-1247

H. E. Hinkel, Jr.
Safety Representative
Pascagoula Metal Trades Council
P. 0. Box 1412
Pascagoula, MS 39568

                                                Amita Gaskins-Rich
                                                Legal Technician
                   UNITED STATES OF AMERICA
       OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION


                                        :

ROBERT REICH, SECRETARY OF LABOR, :
:
Complainant, :
0
a OSHRC Docket
v. 0 Nos. 93-596, 93-597
0 93-614 (Consolidated)
INGALLS SHIPBUILDING, INC., :
:
Respondent, :

        and
                                        0
                                        0

INTERNATIONAL BROTHERHOOD :
OF ELECTRICAL WORKERS, :
LOCAL NO. 773#

        and

PASCAGOULA METAL TRADES COUNCIL, :
AFL-CIO, :
:
Authorized Employee :
Representatives. :
:

              STIPULATION   AND   BETTLEXEWT    AGREEXENT

                                   I

  The parties have reached agreement on a full and complete

settlement and disposition of the issues in this proceeding which

is currently pending before the Commission.

                                   II

  It is hereby stipulated and agreed by and between the

Complainant, Secretary of Labor and the Respondent, Ingalls

Shipbuilding, Inc., that:

  1.   Complainant hereby amends Items 15(j), 15 (k), 15 (n),

WOL 15(P) 8 I5W8 and 15(r) of Serious Citation 1, OSHRC
Docket No. 93-614, to characterize the alleged violations
of 29 CFR 5 1910.303(g)(2)(i) as other-than-serious violations of

the Act. The total proposed penalties for items 15(j), (k), (n),

(o), (p), (q), and (r) is amended to $600. Respondent represents

that these alleged violations have been abated and shall remain

abated by ensuring that the doors on its electrical panel

cabinets shall be kept in a closed position at all times, except

when the electrical panel is being serviced by its electrical

maintenance personnel or when breakers are accessed by authorized

employees. In the event that an authorized electrical servicing

procedure involves the removal of blanks in the panel, Respondent

shall ensure that the blanks are reinstalled in their original

position. When breakers are removed from the panel to eliminate

a circuit, a blank shall be installed.

 20     Complainant hereby amends the proposed penalty for

violation of Serious Citation 1, item 24 of OSHRC Docket No. 930

614 to $4,000. Respondent represents that it shall abate the

alleged violation by instituting a procedure by which a diver in

scuba gear shall be stationed either on the dive barge or

proximate to the underwater point of entry, and be able to

communicate with whomever is manning the air-supply hose at all

times whenever it conducts surface-supplied air diving in

physically confining spaces.

 30     Complainant hereby withdraws items 45(a) of Serious

Citation 1, OSHRC Docket No. 93-614, alleged violation of

§ 1910,181(b) issued to Respondent and the notification of

proposed penalty for that item. Complainant amends the proposed

                               2

penalty for item 45(b) of Serious Citation 1 to $1,750 for the

alleged violation of §l915,335(a)(l)(i). Respondent represents

that employees working on energized circuits shall be required

to use electrical protective equipment to prevent electrical

shock and/or electrical burns. A safety rule requiring the

mandatory use of electrical protective equipment shall be

incorporated into the company's safety policy and disseminated to

its employees through the issuance of the Supervisor% Weekly

Safety Briefing within 60 days from execution of this agreement.

The safety rule shall state that it will be enforced through

means of progressive disciplinary procedures for those employees

found not using the protective electrical equipment. The

Employee Safety Manual shall be amended at its next publication

to include this change.

         4   l      Complainant hereby amends item 1 of Willful Citation

No l 28 OSHRC Docket No. 93-596 (adjudicated by the AIJ as

Serious) to characterize the alleged violation of 51915.36(a)(4)

as a violation of Section 17 of the Act. The proposed

penalty for this citation is amended to $2,500.

Respondent represents that ventilation shall be provided

in sufficient quantities to keep the concentrations of vapors

below ten (10) percent of their lower explosive limit whenever it

engages in painting operations where liquid solvents or paints

are capable of producing a flammable atmosphere. Respondent

shall also ensure that frequent air monitoring tests will be

conducted by a competent person in order to ascertain the

concentration of vapors present during paint operations.
50 Respondent hereby withdraws its notice of contest to the

citations and penalties as referenced and amended herein.

 60   Respondent hereby agrees to pay a penalty of $8,850 by

submitting its check, made payable to U.S. Department of Labor,

Occupational Safety and Health Administration (OSHA) to the OSHA

Area Office within 30 days from date of this Agreement.

 7a   Each party agrees to bear its own fees and other

expenses incurred by each party in connection with any stage of

their proceeding.

 80   None of the foregoing agreements, statements,

stipulations, or actions taken by Ingalls Shipbuilding, Inc.

shall be deemed an admission by Respondent of the allegations

contained in the citations or the complaint herein, nor of the

applicability of any of the standards under the Act which formed

the basis of the citations. The agreements, statements,

stipulations, and actions herein are made solely for the purpose

of settling this matter economically and amicably and they shall

not be used for any other purpose, except for subsequent

proceedings and matters brought by the Secretary of Labor

directly under the provisions of the Occupational Safety and

Health Act of 1970. Respondent reserves all applicable defenses
in the event of future citations involving any of the underlying

facts which formed the basis of any of the citations referenced

herein.

 90   The authorized employee representatives which elected

party status in this case were contacted concerning the terms of

                               4

this Stipulation and Settlement Agreement, and have raised no

objection to the reasonableness of any abatement period set forth

herein.

  10   l   The parties agree that this Stipulation and Settlement

agreement is effective upon execution.
I”lrc
11 l Respondent hereby certifies that on June 7 I 1995, a
copy of this Stipulation and Settlement Agreement was served on

the authorized employee representatives by pre-paid first class

mail in accordance with Commission Rule 7(c). Respondent further
certifies that a copy of this Stipulation and Settlement

Agreement was posted at its worksite in a conspicuous manner on

the 12" day of June 1995, pursuant to Commission Rule 7 and

100, and will remain posted for a period of ten (10) days.
33)
Dated this $ day of June 1995.

                               Respectfully   submitted,

                               THOMAS So WILLIAMSON, JR.
                               Solicitor

                               JOSEPH M. WOODWARD
                               Associate Solicitor for
                               Occupational Safety and Health

                               DONALD Go SHALHOUB
                               Deputy Associate Solicitor for
                               Occupational Safety and Health

                               DANIEL Jo MICK
                               Counsel for Regional
                               Trial Litigation

Attor$ey for Regpondent Attorney for the
P.O. Box 149 Secretary of Labor
Pascagoula, MS 39568-0149 200 Constitution Avenue, NW
Room S-4004
Washington, D.C. 20210

                                 5
 I   certify that a copy of the attached Stipulation   and
                                                            f;w-

Settlement Agreement was mailed postage prepaid on this 7 day
of June, 1995 to the following persons:

           Mr. W.D. McGill
           Business Manager, I.B.E.W.
           Local 733
           P.O. Box 1247
           Pascagoula,  MS   39568
           Mr. H.E. Hinkel, Jr.
           Safety Representative
           Pascagoula Metal Trades Council
           P.O. Box 1412
           Pascagoula,  MS 39568
                                                  lJNffED STATESOF AMERCA
            OCCUPATI’OP                     ‘. SAFETY AND HEALTH RWIE\                                            COMMISSION
                                                    One   tafaay8tt8   c8fltte
                                             1120 20th Street, N.W. -
                                                                    9th Floor
                                                Washington, DC 200364419




SECRETARY OF LABOR,
    Complainant,

                         v.                                                              OSHRC Docket Nos.:

INGALLS SHIPBUILDING, INC.,                                                              93-596; 93497; 93-614
    Respondent,
                                                                                         (Consolidated)
                         and

INTERNATIONAL BROTHERHOOD OF
 ELECTRICAL WORKERS,
 LOCAL NO. 733,

                         and

PASCAGOULA METAL TRADES
 COuNCn, AFL-CIO,
     Authorized Employee
     Representatives.

                                           NOTICE OF DOCKETNG
                                     OF ADMINISTM~    IJ&WJUDGE’S DECISION
       The Administrative Law Judge’s Report in the above referenced case was
   docketed with the Commissi on on November 28,1994. The decision of the Judge
   wilI become a final order of the Commission on December 28,1994 unIess a
   Commission member directs review of the decision on or before that date. ANY
   PARTY DESIRING REVIEW OF THE JUDGE’S DECISION BY THE
   COMMISSION MUST FIlE A PETITIONFOR DISCRETIONARY REVIEW.
   Any such petition should be received by the Executive Secretary on or before
   December 19, 1994 in order to permit sufficient time for its review. See
   Commission Rule 91,29 C.F.R. 2200.91.
      All further pleadings or communications regarding this case shall be
   addressed to:
                                             Executive Secretary
                                             Occupationalsafety and Health
                                              Rewew Commission
                                             1120 20th St. N.W., Suite 980
                                             Washington, D.C 20036-3419
   Petitioning parties shall also mail a copy to:
                                             Daniel J. Mick, Esq.
                                             Counsel for Re ‘onal Trial Iiti ation
                                             Office of the Sof ‘&or, U.S. Ixk
                                             Room S4004
                                             200 Constitution Avenue, N.W.
                                             Washington, D.C. 20210
                                                                                 -   .    e.-   .   .-.   -..c-     ..-.

. . . - SL . ..w-
.
DOCKET NOS. 93-0596 & 93-0597 & 93-0614

If a Direction for Review is issued by the Commission, then the Counsel for
Re$onal Trial Litigation will represent the Department of Labor. Any party
havmg questions about review nghts may contact the Commission’s Executive
Secretary or call (202) 606-5400.
FOR THE COMMISSION

                               fly A/*~~&/$/

Date: November 28, 1994 Ray H. Darling, Jr.
Executive Secretary
DOCKET NOS. 93-0596 & 93-0597 & 93-0614
NOTICE IS GIVEN TO THE FOILOWIN(Ik

Daniel J. Mick, Esq.
Counsel for Region&l Trial I&i tion
Office of the Solicitor, U.S. DOT
Room MOO4
200 Constitution Ave, N.W.
Washingtoq D.C 20210

Associate Regional Solicitor’
Office of the Solicitor
Chambers Bldg., Highpoint Of&e
Center, Suite l50
100 Centeew Drive
l3B AL 35216

Robert J. Ariatti, Jr., Esq.
lglykss;E&;d~ Inc.
Pisiagoula, MS 39568 1049

Mr. W. D. McGill
BusinessManager, LB.E.W.,
Lcxxl733
P.O. Box 1247
Pascagoula,MS 39568 I247

Mr. H. E. Hinkel, Jr., Safety
Representative
P oula Metal Trades Council
P!iY?ox 14l2
Pascagoula, MS 39568

Nancy J. Spies
AdmmistrativeLaw Jud e
Occupational Safety and Health
Review Commission
1365 Peachtree St., N. E.
Suite 240
Atlanta, GA 30309 3119

OOlOI397388:04
UNITED STATES OF AMERICA
OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION
1365 PEACHTREE STREET, N.E., SUITE 240
ATLANTA, GEORGIA 30309-3119

PHONE: FAX:
COM (404)347-4197 COM (404)347-0113
FTS(404)347-4197 FTS(404)347-0113

                                                         .
                                                         .

SECRETARY OF LABOR, 0
.

 Complainant,                                           .
                                                         .



                                                        .
                                                        .




             V.
                                                        .
                                                        .                  OSHRC Docket Nos.:
                                                                   ..

INGALLS SHIPBUILDING, INC., b. 93-596; 93-597; 93-614
Respondent, ..
.. (Consolidated)
and ..
b.
INTERNATIONAL BROTHERHOOD OF ..
ELECTRICAL WORKERS, .b
LOCAL NO. 733, ..
..
and ..
..
PASCAGOULA METAL TRADES ..
COUNCIL, AFL-CIO, ..
Authorized Employee .b
Representatives. bb
..

Appearances:

      Cynthia Welch-Brown, Esquire                                        Robert J. Ariatti, Jr., Esquire
              Office of the Solicitor                                             Ingalls Shipbuilding, Inc.
              U. S. Department of Labor                                           Pascagoula, Mississippi
              Birmingham, Alabama                                                          For Respondent
                      For Complainant

Before: Administrative Law Judge Nancy J. Spies

                                  DECISION AND ORDER

      On July 28,1992, the Occupational      Safety and Health Administration                    (OSHA) began

a safety inspection of a shipyard owned and operated by Ingalls Shipbuilding, Inc. (Ingalls),
in Pascagoula, Mississippi. The safety inspection resulted from the filing of a formal
complaint. It was expanded to a general inspection because Ingalls appeared on OSHA’s
high hazard list, which lists employers with high accident rates (Tr. 15-16). OSHA began a
health inspection on August 5, 1992, which was limited in scope to complaint and referral
items from the OSHA safety inspectors. On September 30, 1992, OSHA began a fatality
inspection at Ingalls’ shipyard.
On January 26, 1993, the Secretary issued to Ingalls citations for serious and “other”
violations found in the safety inspection (Docket No. 93-614); for willful, serious, and “other”
violations found in the health inspection (Docket No. 93-596); and for serious violations
found in the fatality inspection (Docket No. 93-597). Ingalls contested various aspects of the
citations and penalties. The Secretary filed a notice of dismissal on March 30, 1993,
withdrawing one of the cited items.
A hearing was held in these matters from December 13 through 16, 1993. The
undersigned consolidated the three cases for the purposes of holding one hearing and issuing
one decision. Prior to the hearing, the Secretary and Ingalls reached agreements on several
of the contested items. The parties entered into two stipulations and joint motions
(Exhs. J-l, J-2), and the Secretary entered a notice of dismissal of one of the items
(Exh. J-3).

                           Docket No. 93-614: The Safety Inspection

    On July 28, 1992, OSHA Compliance                    Officers James Pinnix, Nate Williams, and

Courtney Bohannon arrived at Ingalls’ shipyard in response to a formal complaint
(Tr. U-16). They held an opening conference with Ingalls’ director of industrial relations
services, Don Massengale; its safety manager, Glenn Harris; and safety supervisor Harvey
Bond. Two union representatives were also present, one from the metal trades union and
one from the electrical workers’ union (Tr. 17-18, 421).
After the opening conference, Pinnix began a walk-around inspection of the shipyard.
The entire inspection lasted approximately one month. Pinnix was accompanied by Harris
and Bond, and by another Ingalls safety supervisor, John Fleming. Compliance Officer
Bohannon was assigned to review Ingalls’ records. Compliance Officer Williams

                                                     2

accompanied Pinnix for the first week of the safety inspection and then proceeded on his
own for the rest of the inspection (Tr. 18-20).

                      Citation No. 1: Alleged Serious Violations
                              Item 3a: 5 1910.23(d)(l)(i)

   Item 3a alleged two instances aboard a ship under construction           in which Ingalls

violated 0 1910.23(d)(l)(i), which provides:

   (d) Stairway railings and guards. (1) Every flight of stairs having four or
   more risers shall be equipped with standard stair railings or standard handrails
   as specified in paragraphs (d)(91)(i) through (v) of this section, the width of
   the stair to be measured clear of all obstructions except handrails:

           (i) On stairways less than 44 inches wide having both sides
           enclosed, at least one handrail, preferably on the right side
           descending.

   In instance (a), a metal structure in a location designed as 01-61-2-L in module No. 2

was not equipped with a handrail. The structure was enclosed on both sides. The steps
were approximately 30 inches wide, and there were 9 inches between the risers. Pinnix
measured the height of the structure at 9 feet 8 inches. The steps were accessible to the
employees working in the area (Exh. C-l; Tr. 21-23).
Instance (b) involves a metal structure, less than 44 inches wide, located at 2-53-2-L
in module No. 2 that was not equipped with a handrail. The structure was 8 feet 5 inches
high and was accessible by Ingalls’ employees (Tr. 23-24).
The hazard created by the failure to have at least one handrail is that an employee
could fall while ascending or descending the steps (Tr. 22). The likely result of such a fall
could include broken bones and serious cuts and bruises (Tr. 37).
In order to prove a violation of a 5 5(a)(2) standard, the Secretary must establish four
elements: “(1) the standard applies, (2) the employer failed to comply with the terms of the
standard, (3) employees had access to the cited condition, and (4) the employer knew or,
with the exercise of reasonable diligence, could have known of the violative condition.”
Wheeling-Pittsburgh Steel Corporation, 16 BNA OSHC 1780, 1782, 1994 CCH OSHD ll ,
(No. 91-2524, 1994).
Ingalls does not dispute the facts regarding the dimensions of the structures, nor does
it dispute that handrails were not provided. That the Secretary established the last three
elements of the violation is uncontested: Ingalls failed to equip the structures with handrails,
its employees had access to the unrailed steps, and Ingalls knew that this condition existed
since the structures were in plain view.
Ingalls argues, however, that the Secretary failed to establish the first element of the
violation that the cited standard applies. Section 1910.23(d) is captioned “Stahay railings

and guardis.” Ingalls contends that the structures in question are ladders and not stairways.
As such, these structures would be covered in the general industry standards by 0 1910.27
(Fixed Ladders), or in the maritime standards by 5 1925.72 (Ladders). Neither ladder
standard requires that handrails be placed on ladders. Ingalls points out that Ingalls’ plans
and specifications for the ship at issue refer to the structures as “ladders” (Exhs. R-9, R-10,
R-11; Tr. 318-320). The plans called for handrails to be installed on the structures.
Section 1910.23(d) appears in Subpart D (Walking-Working Surfaces). The definition
section of that subpart, 0 1910.21, provides little guidance in differentiating between
stairways and ladders. Section 1910.21(b)(8) provides:

      (8)   Stain or stairways. A series of steps leading from one level or floor to
      another, or leading to platforms, crossovers, or around machinery, tanks, and
      other equipment that are used more or less continuously or routinely by’
      employees, or other occasionally by specific individuals. A series of steps and
      landings having three or more risers constitutes stairs or stairway.

      Sections 1910.21(c)( 1) and (e)( 1) provide:

      Ladders.   A ladder is an appliance usually consisting of two side rails joined
      at regular intervals by crosspieces called steps, rungs, or cleats, on which a
      person may step in ascending or descending.

      Both of these definitions apply to the structures at issue. The photograph         identified

as Exhibit C-1 could be used to illustrate either definition.
Under cross-examination, Pinnix was asked what criteria he used in determining
whether the structures were stairways or ladders. Pinnix replied (Tr. 106):
The area that I used to determine a stairway or a ladder is - - of course, it’s
got to have more than four steps on it. And, the ladder being more of a
temporary use than the stairway.

      A stairway would be used or would be there for continuous use of employees
      where a ladder would be for a temporary use.

      Pinnix’s definition of a ladder as temporary is contradicted           by 8 1910.21(e)(2), which

defines “fixed ladder”: “A fixed ladder is a ladder permanently attached to a structure,
building, or equipment.” Temporary use is not, therefore, a defining characteristic of a
ladder.
Pinnix advanced another distinction between ladders and stairways (Tr. 107):
“A ladder, you ascend a ladder facing the ladder and you descend it facing the ladder.
Stairwavs. vou ascend a [stairway] facing it and descend it facing away from it.” Pinnix’s
J ’ d

distinction is not found in the OSHA standards. Rather, it is Pinnix’s “professional view”
(Tr. 107). While Pinnix comported himself as an experienced, credible witness, his subjective
interpretation of how stairways should be used as compared to ladders cannot be grafted on
.
as a requirement of the OSHA standard.
The Secretary failed to provide any distinction found within OSHA law that would
help to elucidate the difference between stairways and ladders.
1
Ingalls, on the other hand,
points out that 6 1910.24(e), which governs “Fixed industrial stairs,” provides in pertinent
part ..

      Angle of stairway tie.
                           Fixed stairs shall be installed at angles to the horizontal
      of between 30’ and 50’.

      Pinnix did not measure the angles of the structures to the horizontal (Tr. 108). Keith

Breland, an engineering supervisor for Ingalls, testified that the structures in question were
required to be installed at angles of 50’ to 60’ to the deck (Tr. 313, 315).
The Secretary argues that the angle of installation is not determinative of what the
structure is, but he fails to explain what is determinative. He states in his post-hearing brief
that “one has only to look at the Secretary’s Exhibits C-l through C-10 to see that they are
indeed stairs” (Secretary’s Brief, p. 6). An examination of the referenced exhibits reveals
that they consist of “two side rails joined at regular intervals by crosspieces called steps . . .

                                                    5

on which a person may step in ascending or descending,” which is OSHA’s definition of a
ladder. The one distinguishing characteristic of stairways that appears in the regulations, the
angle of the rise, does not apply to the structures at issue.
Accordingly, it is concluded that the Secretary failed to prove that 0 1910.23(d)(l)(i),
which applies to stairways, applies to the structures cited in item 3a. Those structures are
determined to be ladders, which OSHA does not require to be equipped with handrails.
Item 3a will be dismissed.

                                Item 3b: 5 1910.23(d)(l)(ii)

   The Secretary charges Ingalls with five instances of violating 6 1910.23(d)( l)(ii), which

provides that stairwavs with four or more risers be equipped as follows:

   (ii) On stairways less than 44 inches wide having one side open, at least one
   stair railing on open side.

   The width of the stairs in instances (a) through (e) were all less than 44 inches

(Tr. 23). The fall distance in instances (a) and (b) was 7 feet 6 inches (Tr. 26). Pinnix did
not measure or estimate the fall distance for instance (c) (Exh. C-2; Tr. 27-28). The fall
distance in instance (d) was 10 feet 7 inches (Exh. C-3; Tr. 29). In instance (e), Pinnix
estimated the fall distance to be 40 inches (Tr. 29-30).
As in item 3a, the structure cited as “stairways” are determined to be “ladders.”
Therefore, the cited standard does not apply. Item 3b will be dismissed.

                                Item 3c: 5 1910.23(d)(l)(iiil

   In seven instances (instance (b) was withdrawn by the Secretary prior to the hearing),

the Secretary alleges that Ingalls violated 0 1910.23(d)(l)(iii), requiring “[on] stairways less
than 44 inches wide having both sides open, one stair railing on each side.” Pinnix observed
the following instances of structures less than 44 inches wide, having both sides open:

   Instance                  Fall Distance                Exhibit                Tr
                                                                                 A

         a                   7 feet 4 inches                c-3                   30
         C                                                  c-4                   31
         d                   6 feet !kches                  c-5                   32


                                               6
    Instance                  Fall Distance                Exhibit               Tr
                                                                                 u-2

        e                     9 feet 9 inches                 C-6                 33
        f                     9 feet 9 inches                 c-7                 34
        g                     9 feet                          C-8                 34-35
        h                     9 feet                          c-9                 35

    The structures that the Secretary cited as stairways were ladders. The cited standard

does not apply. Item 3c will be dismissed.

                                 Item 36: B 1910.23(d)( l)(iv’)

    Ingalls contested the penalty and the serious classification of item 3d, which alleges

a violation of 8 1910.23(d)(l)(iv). The standard requires:

    (iv) On stairways more than 44 inches wide but less than 88 inches wide, one
    handrail on each enclosed side and one stair railing on each open side.

    Pinnix observed a wooden stairway leading up to a restroom in a mobile trailer. The

stairway had a handrail on the left side ascending, but not on the right side, which was open.
The fall distance was 5 feet (Exh. C-10; Tr. 36). Likely injuries resulting from a fall the
stanway could include broken bones and serious cuts and bruises (Tr. 37).
Ingalls argues that its violation of 8 1910.23(d)(l)(iv) was not serious because the
installation of a handrail on one side mitigated the possibility of injury. This argument is
rejected. If an employee fell while ascending or descending near the unguarded side, the
one existing handrail would be of little benefit to him or her. The possibility of injury
remains. Item 3d is properly classified as serious.
In determining the penalty for a violation, 3 17(j) of the Act requires the Commission
to give “due consideration . . . to the size of the business of the employer being charged, the
gravity of the violation, the good faith of the employer, and the history of previous
violations.”
Ingalls employs approximately 20,000 employees (Tr. 40). The gravity of the violation
was of moderate severity, the fall was only 5 feet and there was a railing on one side of the
stairway. There was no evidence of lack of good faith on Ingalls’ part. Ingalls had received
a citation for a serious violation of the Act during the relevant period (Tr. 41). Upon due
consideration of these factors, it is determined that a penalty of $500.00 is appropriate?

                                   Item 15: 5 1910.303(g)(2)(i)

     The Secretary alleged that Ingalls violated 6 1910.303(g)(2)(i) in eighteen instances.

The cited standard provides:

     (2)   Guarding of live parts. (i) Except as required or permitted
                                                                     elsewhere in
     this subpart, live parts of electric equipment operating at 50 volts or more
     shall be guarded against accidental contact by approved cabinets or other
     forms of approved enclosures, or by any of the following means:

              (A) By location in a room, vault, or similar enclosure that is
              accessible only to qualified persons.

              (B) By suitable permanent, substantial partitions or screens so
              arranged that only qualified persons will have access to the
              space within reach of the live parts. Any openings in such
              partitions or screens shall be so sized and located that persons
              are not likely to come into accidental contact with the live parts
              or to bring conducting objects into contact with them.

              (C) By location on a suitable balcony, gallery, or platform so
              elevated and arranged as to exclude unqualified persons.

             (D) By elevation of 8 feet or more above the floor or other
             working surface.

    The Secretary cited the following instances:

     (a)     Exposed 110 V/AC from two broken light bulbs in temporary lighting
             at Ol-77.2L on LHD No. 4.

     (b)      Exposed 110 V/AC from one missing bulb in temporary                        lighting at
              02-81-O-C on LHD No. 4.

     (c)     Exposed 110 V/AC from two missing light bulbs in temporary lighting
             at 1-67-2-L area on LHD No. 4.

’ The analysis of three of the relevant factors, Le., the size of Ingalls’business, its good faith, and its history
of previous violations will, of course, remain constant with regard to the determination of penalties for other
violations found in this case. The only variable factor will be the gravity of the violation.

                                                    8

((9 Exposed to 110 V/AC from one missing light bulb in temporary lighting
at 02-49-4-L on Module 2.

0e Exposed 110 V/AC from missing bulb in temporary lighting at 6-53-2-M
AM0 magazine in Module 1.

(0 Exposed to 110 V/AC from broken light bulb in temporary lighting at
2-167-2-L on LHD No. 4.

(g> Exposed 110 V/AC from broken light bulb in temporary lighting at
AMR engine room No. 2 ship 4521.

09 Light bulbs were broken out on walkway next to restrooms on walkway
into Ship 4521, creating hazard of electrical shock to employees.

0i Exposed 110 volt from broken bulb in temporary lighting at 01
Weather Deck, forward port Ship 4522.
.
0) Locker Shop - Knock out blank was missing in the 220/120 volt
electrical control panel box.

w Pump shop, 4A Warehouse - Knock out blank missing in the 220/208
volt electrical panel.

(1) Cover missing from start/stop controller box on 220 V/AC flushing
pump motor at No. 2 Engine Room on Ship 7202 creating hazard of
electrical shock to employees. * penalty only

(m 1 Rigging Shop, South Wall - Open and energized 480 V circuit breaker
panel exposed employees to accidental contact with live parts.
* penalty only

(n > Tire Shop, Northeast Wall, near Water Cooler - One single
breaker/blank was missing from a 208V circuit breaker panel, exposing
employees to accidental contact with live parts.

(0 > Kevlar Shop - Five single breakers/blanks were missing from a
48Ov circuit breaker panel, exposing employees to accidental contact
with live parts.

(PI Kevlar Shop North wall - 2 single breakers/blanks were missing from
a 208V circuit breaker panel exposing employees to accidental contact
with live parts.

                                 9
       (q)     Shell Sh op, PLA Middle Bay lights circuit breaker panel - Three single
               breakers/blanks were missing from a 480V circuit breaker panel.

       (r)     East bank, wetdock restroom (T-8 bathroom), supply room - Nine
               single 20A breakers/blanks were missing from 1lOV circuit breaker
               panel exposing employees to accidental contact with live parts.

       Ingalls argues that the Secretary has again cited an inapplicable   standard.      Ingalls

contends that because the alleged violations occurred in areas where the maritime standards
applied, the Secretary was wrong to cite Ingalls under the general industry standards for
instances. 15(a) through 15(i), which existed on shipboard.
The relationship between the general industry standards and the maritime standards
is explained in 8 1910.5(c), which provides in pertinent part:

       (c)(l)    If a particular standard is specifically applicable to a condition,
       practice, means, method, operation or process, it shall prevail over any
       different general standard which might otherwise be applicable to the same
       condition, practice, means, method, operation or process . . . .

       (2) On the other hand, any standard shall apply according to its terms to any
       employment and place of employment in any industry, even though particular
       standards are also prescribed for the industry . . . to the extent that none of
       such particular standards applies.

       The Secretary points to OSHA Instruction       STD.2, which identifies those general

industry standards that are applicable to shipyard work (Exh. C-31). Appendix A to the
instruction identifies 8 1910.303 as being applicable to shipyard employment (Exh. C-32,

P . 8) .
An OSHA instruction is only an internal memorandum that provides guidance to
OSHA personnel. It has no binding affect on the Review Commission. The Commission
is, however, bound by the OSHA standards themselves. Sections 1910.302 through 1910.308
address electric utilization systems. Section 1910.302(a)(2) provides in pertinent part:

       (2)   Not covered.    The provisions of 35 1910.302 through 1910.308 of this
       subpart does not cover:
              (i) Installations in ships, watercraft . . .




                                              10
    Section   1910.302(a)(2)(i)     clearly exempts     electrical   installations   on ships from

coverage by 6 1910.303. Therefore, 6 1910.303(g)(2)(‘)1 is inapplicable to the cited conditions
to the extent that they existed on ships. The Secretary has failed to establish an essential
element of his case for items 15(a) through 15(i).
In contrast, instances 15(j), (k), (n), (o), (p), (q), and (r) pertain to openings in
faceplates on junction boxes located throughout the shipyard. Only the proposed penalties
were contested *for instances 15(l) and (m). After considering the specific facts involved in
each instance, and in spite of the fact that some openings were small, the violations are
affirmed. The sizes of the openings were sufficient to allow accidental contact with fingers
or tools. Also, even though the panel door might have been closed in some instances,
electricians or others seeking to work in the panels would have been exposed. The fact that
a panel door was closed affects the gravity of the violation. Ingalls has instituted a
procedure which seeks to identify such violations. However, most of the instances were in
plain sight. The quantity of such electrical violations establishes that its program could have
been more effectively implemented. Ingalls had knowledge of the violations. Having
evaluated the gravity of the specific instances, instances 15(j), (k), and (r) are assessed at
$120.00 each; instances 15(n) (o), (p) and (q) are assessed at $100.00 each; and instances
15(l) and (m) are assessed at $200.00 each, for a total penalty of $l9l6O.OO.

                                  Item 23: $ 1910.422(b)(3)

    The Secretary charged Ingalls with a serious violation of 8 1910.422(b)(3), which

provides:

    (b) Water entry and exit. (3) A means shall be provided to assist an injured
    diver from the water or into a be11.2

    During his inspection Pinnix observed Ingalls’ divers in operation.                 Divers were

required to check for leaks, inspect underneath the ships, and replace timbers and do any
other work required below the surface of the water (Tr. 67, 223).

Section 1910.402 defines a bell as “[a]n enclosed compartment, pressurized (closed bell) or unpressurized
(open bell), which allows the diver to be transported to and from the underwater work area and which may
be used as a temporary refuge during diving operations.

                                                11
   Pinnix observed that the diving barge was equipped with a ladder, which he believed

was the only means available to remove an injured diver from the water (Tr. 68). Pinnix
suggested that Ingalls have a stokes basket (an emergency basket which can be lowered into
the water for the purpose of putting the injured diver into it and lifting it from the water)
installed on the diving barge and capable of being lifted mechanically (Tr. 68-69, 72). Ingalls
had baskets at various locations throughout Ingalls’ worksite, but none at the diving barge
(Tr. 71-72).
Randy Sonnier is Ingalls’ tender foreman and dive master for the dive crew. He has
worked for Ingalls for over 19 years (Tr. 223). Sonnier testified that the diving barge is
usually anchored or tied to a ship or structure and that the crew operates from the diving
barge or the tender. The tender may be located away from the barge, at the side of the ship
or structure, or in the waterway (Tr. 225). When the divers are working from the diving
barge, there is no mechanical means to assist a diver from the water. If a diver is injured,
the other divers help take him to the dock, where he is lifted from the water (Tr. 224). In
an emergency, the divers could get an injured diver out of the water if the injured diver was
near a gantry crane. Sonnier stated, “There’s normally a gantry available somewhere in the
yard. It’s just depending on where we’re diving at as to how we can get to it” (Tr. 243).
Sonnier estimated that the greatest amount of time needed to get an injured diver
to the dock where an ambulance could pick him up would be four minutes (Tr. 265).
Sonnier recalled only one instance in which an Ingalls’ diver was ever injured. The diver was
lifted into the diving boat and transported to the East Bank dock where an ambulance was
waiting. From the time the diver lost air to the time he was placed in the ambulance was
“probably two to three minutes” (Tr. 241-242).
The Secretary argues that Ingalls violated 0 1910.422(b)(3) by failing to provide a
mechanical means on the diving barge by which to remove an injured diver from the water.
“The fact that Ingalls has baskets at the shipyard, gantry cranes at the docks, and a pair of
hands in the skiff does not mean that it has complied with the standard” (Secretary’s
Brief, p. 15). The Secretary emphasizes the time factor as crucial to complying with the
standard: “While there is no case law which interprets 5 1910.422(b)(3), the Secretary

                                           12

submits that the requirement for a means to assist an injured diver from the water must
logically encompass a requirement for a readily available means” (Secretary’s Brief, p. 15).
There are two flaws with the Secretary’s argument. First, he is reading a requirement
into the standard that does not appear in the clear language of the standard. The standard
requires that “[a] means shall be provided to assist an injured diver from the water or into
a bell.” Obviously, the “means” should be effective. However, the Secretary is not free to
impose a subjective interpretation of an inferred requirement upon employers.
Second, the Secretary has failed to prove his own additional requirement, that Ingalls’
means of assistance was not readily available. Ingalls presented undisputed testimony that
the greatest amount of time needed to retrieve an injured diver from the water and get him
to emergency medical personnel is four minutes. The Secretary failed to adduce any
evidence establishing what he believes to be an acceptable minimum amount of time for the
means of assistance to comply with the standard. No testimony was given that proved that
four minutes is outside the range of what the Secretary considers “readily available.”
The Secretary has failed to establish that Ingalls was in violation of 8 1910.422(b)(3).
Item 23 is dismissed.

                                 Item 24: ($ 1910.425(c)(2)

   Section 1910.425(c)(2) provides:

   (c) Procedures. (2) A diver shall be stationed at the underwater point of
   entry when diving is conducted in enclosed or physically confining spaces.

   From employee interviews, Pinnix learned that Ingalls’ divers are required at times

to work underneath the pontoon at the dry dock. The pontoon rests on a grid structure
when it is at dockside. Ingalls’ divers perform a variety of tasks underneath the pontoon:
“replace parts of the grid structure itself, bottom surveys, video inspections, repair work,
patch leaks” (Tr. 228).
Sonnier described the grid structure as thick concrete structures 16 feet square by
3 feet which were adjoined end-to-end for the length of the pontoon, which is 200 feet by
600 feet. The grid structure has 60 rows and each row has 11 sections. Each section has
4 pilings and 4 piling caps with 1 grid section and 2 grid timbers (Tr. 228-229). The grid

                                             13

structure is fifteen feet below the surface of the water and directly under the pontoon
(Tr. 23 1).
Pinnix testified that he considered the timbers of the grid structure to be a confined
space (Tr. 76):

    Well, first of all it has limited egress and exit ways from it. It’s definitely not
    an area where it’s a continuous work area and it’s -- of course, their vision is
    so limited under there, it’s hard to see, you know, sometimes eight or twelve
    inches beyond their face. So, therefore, I considered it a confined space.

    Both the Secretary’s counsel and Pinnix referred to the area underneath      the dry dock

as a “confined space” and spoke of the standard as applying to a “confined space.” The
standard, however, applies to “enclosed or physically confining spaces.”
Indeed, the definitions of “confined space” found in the standards would appear to
work against the Secretary’s interpretation of the area at issue as a confined space.
Subpart T, which contains the commercial diving operations standards and in which the cited
standard is found, does not provide a definition of either “physically confining spaces” or
“confined spaces.” Section 1915.4 contains the definitions for the maritime standards. It
provides:

   (p) The term “confined space” means a compartment of small size and
   limited access such as a double bottom tank, cofferdam, or other space which
   by its small size and confined nature can readily create or aggravate a
   hazardous exposure.

   (q) The term “enclosed space” means any space, other than a confined space,
   which is enclosed by bulkheads and overhead. It includes cargo holds, tanks,
   quarters, and machinery and boiler spaces.

    Subpart Q (Welding, Cutting and Brazing) of the 5 1910 standards              provides at

§ 1910.252(b)(4) that “As used herein confined space is intended to mean a relatively small
or restricted space such as a tank, boiler, pressure vessel, or small compartment of a ship.”
What all of these definitions have in common is the idea of a compartment, or a man-made
restricted space. They clearly do not apply to the underwater area at issue here.

                                               14
   The crucial question is whether or not the area underneath                       the dry dock is a

physically confining space. The Secretary does not argue that it is an enclosed space. Pinnix
gives three reasons for recommending a citation for the violation of 0 1910.425(c)(2):

      (1)         The area underneath    the dry dock “has limited egress and exit ways
                  from it”;

      (2)         The area is “definitely not an area where it’s a continuous work area”;
                  and

      (3)         The diver’s “vision is so limited under there, it’s hard to see, you know,
                  sometimes eight or twelve inches beyond their face.”

(Tr. 76).

      Pinnix’s third reason is easily dismissed. The standard applies to “physically confining

spaces,” not visually confining spaces. The standard imposes no requirements for spaces
where vision is limited.
Pinnix’s second reason, that the area is not a continuous work area, does not appear
to have any relevance to the cited standard. Not being the site of continuous work does not
render an area as a physically confining space. This reason, too, can be dismissed.
This leaves Pinnix’s first reason as his sole justification for recommending a citation
for the violation of 5 1910.425(c)(2). Pinnix stated that the area beneath the dry dock “has
limited egress and exit ways from it.” Sonnier testified that, while the divers could exit from
underneath the grid structure by swimming out in any direction (north, south, east, or west),
they did not have “free access to the surface” (Tr. 268, 272). Sonnier stated that within the
diving industry, a physically confining space is “any space where the diver doesn’t have a free
access to the surface” (Tr. 268). Sonnier reiterated that the divers did not have access to
the surface when the pontoon was on the grid structure (Tr. 268). In that case, the bottom
of the pontoon would act as the “ceiling” to the divers’ work area, cutting off their access
to the surface (Tr. 269). Based upon Sonnier’s testimony, it is determined that the area
beneath the grid structure is a physically confining space within the meaning of
gi 1910.425(c)(2).

                                                  15
     Sonnier admitted that Ingalls does not station a diver at the point of entry when a

diver is required to work beneath the grid structure (Tr. 232). Walter Roberts, another
diver for Ingalls, agreed that divers were not stationed at the point of entry when work is
being done below the grid structure (Tr. 279). Ingalls points out that it always has divers
work in pairs in case one of the divers encounters trouble (Tr. 249-250, 279). Ingalls
contends that its divers prefer working in pairs and that the spirit of the standard is met by
its use of the buddy system.
Unfortunately for Ingalls, it does no good to meet the spirit of the standard when the
actual requirements of the standard are being violated. The preference of Ingalls’ divers
cannot be substituted for compliance with the language of 5 1910.425(c)(2). Ingalls has
conceded that it failed to station a diver at the point of entry for a physically confining
space. The hazard created by Ingalls’ failure to comply is that of drowning (Tr. 77). A
serious violation of 8 1910.425(c)(2) is found.
The gravity of the violation is severe. A penalty of $5,000.00 is appropriate.

                                 Item 32: $ 1915.72(a)(l)

     The Secretary charges Ingalls with four instances of violating 5 1915.72(a)(l), which

provides:

     (a) Gelter& requirements. (1) The use of ladders with broken or missing
     rungs or steps, broken or split side rails, or other faulty or defective
     construction is prohibited. When ladders with such defects are discovered,
     they shall be immediately withdrawn from service. Inspection of metal ladders
     shall include checking for corrosion of interiors of open end, hollow rungs.

     All four instances involved 6-foot wooden ladders. The hazard created was a 6-foot

fall onto the metal landing of the ship. In instance (b), the top rung of the ladder was
broken (Exh. C-22; Tr. 80). Instance (c) involved a broken spreader. The spreader’s
function is to hold the legs of the ladder together (Exh. C-23; Tr. 81). Instance (d) also
involved a broken spreader. Exhibit C-24 shows where Ingalls attempted to repair the
spreader using tape (Tr. 82). In instance (e), the ladder had a broken top platform
(Exh. C-25; Tr. 82-83).

                                               16
    Each of the four ladders in question was available for use by the employees on the

ship. Employees indicated to Pinnix that the ladders were to be used. The ladders were not
tagged or removed from service. The hazardous condition of the ladders could have been
abated by removing them from the ship or by repairing them (Tr. 83). The most likely
injuries that would result from a fall from one of the defective ladders were sprains and
broken bones (Tr. 84).
Ingalls argues that Pinnix failed to observe an employee actually using any of the four
ladders. Ingalls also contends that no employees told Pinnix that they were required to use
the defective ladders or that they reported the condition of the ladders to their supervisor.
All of this is irrelevant to the establishment of a violation of 5 1915.72(a)(l). The Secretary
has established that Ingalls’ employees had access to the ladders, which is sufficient to prove
a violation.
Joseph Krebs was director of Ingalls’ electrical department at the time of OSHA’s
inspection (Tr. 354). Krebs testified that Ingalls’ supervisors did not allow their employees
to use broken wooden ladders. Krebs stated, “We supplied them with new ladders
consistently. We bought new ladders all the time for them” (Tr. 356). Krebs stated that a
broken ladder “is supposed to be taken out of service” (Tr. 358). Krebs described Ingalls’
policy (Tr. 356-357):

    None of our workmen are allowed to work on ladders that had any defective
    rungs or defective legs.

    They were not allowed to stand at the last step of the top of the ladder. And,
    if the ladder becomes rickety, they should take it out of service, which in most
    cases, they always do. We destroy them.

    iEmployees] can get a replacement ladder easily; they check them out. They
    are a check-out item out of the tool room.

    Donald     Massengale,   Jr., is the director of industrial relations   services at Ingalls

(Tr. 421). Ingalls sends out documents to its supervisor entitled “Supervisors Weekly Safety
Briefings” and “Job Safety Bulletins” (Exh. R-21; Tr. 423). Massengale referred to three
separate briefings regarding inspection of broken or damaged ladders (Tr. 426-428).

                                             17
   The testimony of Krebs and Massengale does not negate, however, the observations

made by Pinnix. Despite Ingalls’ stated policy, Pinnix observed four defective ladders that
were available for use and were not marked as defective. A company’s safety policy does
no good unless it is effectively enforced. The Secretary has established violations of
8 1915.72(a)( 1).
The possible injuries resulting from the hazard (sprains and broken bones) are
serious. The violation is of medium gravity. A total penalty of $3,500.00 is appropriate for
the four instances.

                                    Item 35: !$ 1915.73(c\

   Section 1915.73(c) provides:

   (c) When employees are working around open hatches not protected by
   coamings to a height of 24 inches or around other large openings, the edge of
   the opening shall be guarded in the working area to a height of 36 to
   42 inches, except where the use of such guards is made impracticable by the
   work actually in progress.

   The Secretary        alleged   two instances where employees       were exposed      to open

hatchways with no attached railings. Instances (c) and (d) are depicted in the photographs
admitted as Exhibits C-26, C-27, and C-28 (Tr. 87-88). The hazard presented was that of
employees stepping or falling into the open hatches. The fall distance to the deck below was
approximately 9 feet (Tr. 88). Possible injuries sustained in such a fall include lacerations,
cuts, bruises, and broken bones (Tr. 89).
Ingalls did not contest the citation for the violation of 6 1915.73(c), but did contest
the penalty. The Secretary has established a serious violation of the standard, with medium
gravity of the violation. A penalty of $3,500.00 is assessed.

                                    Item 39: S 1915.91(c)

   Section 1915.91(c) provides:

   Slippery conditions on wallnvays or working surfaces shall be eliminated            as
   they occur.



                                               18
   Compliance     Officer Nathaniel Williams observed three instances on the east bank

where he believed Ingalls was in violation of 0 1915.91(c). That standard, which is part of
the maritime standards, is inapplicable to the two shops involved in instances (i) and (j)
The violation for instance (k) was not contested, and only the penalty is at issue.
Section 1915.91 specifies, “The provisions of this section shall apply to ship repairing,
shipbuilding and shipbreaking except that paragraphs (c) and (e) of this section do not apply
to shipbreaking.” Because paragraph (c) is the section at issue, it applies only to ship
repairing and shipbuilding. Section 1915.4 is the definition section of the maritime
standards. Sections 1915.4(j) provides:

   The terms “ship repair” and “ship repairing” mean any repair of a vessel
   including, but not restricted to, alterations, conversions, installations, cleaning,
   painting, and maintenance work.

   Section 1915.4(k) provides:

   The term “shipbuilding” means the construction of a vessel including, but not
   restricted to, alterations, conversions, installations, cleaning, painting, and
   maintenance work.

    Ingalls argues that ship repairing       and shipbuilding   as defined     by the maritime

standards do not include work done in pipe and machine shops located on the banks of a
waterway. Persuasive support for this view is found in Dravo Corp. v. OSHRC,
613 F.2d 1227 (3d Cir. 1980).
In Dravo, the Secretary cited Dravo for violations of the maritime standards following
an OSHA inspection of the structural shop of Dravo’s Engineering Works Division on
Neville Island, Pittsburgh, Pennsylvania. Dravo contested the citations, which were affirmed
by the administrative law judge. Dravo appealed to the Third Circuit Court of Appeals,
which set aside that part of the administrative law judge’s decision holding the OSHA
maritime standards applicable to Dravo’s structural shop.
The Third Circuit focused on the definitions given in the maritime standards for
“employer” and “employee.” Section 1915.4(c) provides:

    The term “employer” means an employer, any of whose employees are
    employed, in whole or in part, in ship repairing, shipbuilding, shipbreaking or

                                               19
   related employments as defined in this section on the navigable waters of the
   United States, including dry docks, graving docks and marine railways.

   Section 1915.4(d) provides:

   The term “employee” means any person engaged in ship repairing,
   shipbuilding, shipbreaking or related employments on the navigable waters of
   the United States, including dry docks, graving docks and marine railways,
   other than the master, ship’s officers, crew of the vessel, or any person
   engaged by the master to repair any vessel under 18 net tons.

   Looking at what the maritime            standards   include, the Third Circuit reasoned    as

follows:

   Because the Secretary has failed in his regulations to state that a structural
   shop is included with docks and marine railways as a place of maritime
   employment to which shipbuilding regulations apply, we believe that the
   structural shop at issue here is not to be held to shipbuilding safety standards.
   The Act grants the Secretary, and not OSHRC or the courts, the means and
   the responsibility to amend the regulation if he so desires . . . . Which areas
   besides waters, docks, and marine railways are covered is unclear.

Draw, 613 F.2d at 1232-1233. Thus, the Third Circuit declined to expand the coverage of
the maritime standards to the structural shop because it was not an area specified in the
standards. “[A]n employer should not be subject to penal sanctions for nonadherence to
safety standards without adequate notice in the regulations of the exact contours of his
responsibility.” Ibid at 1234.

    The court’s reasoning in Draw is applicable here. The pipe shop and machine shop

on the east bank of the waterway are not the types of areas specified in the maritime
standards as coming under their jurisdiction. Therefore, it is concluded that 6 1915.91(c) is
inapplicable to the cited conditions. Items 39(i) and (j) are dismissed. Instance 39(k)
involved leaking hydraulic oil where employees could possibly slip into lathes or other
operating equipment. Maintenance had been previously alerted to the condition, which was
abated after the OSHA inspection. A penalty of $325.00 is assessed.

                                               20
                                   Item 40: $ 1915.92(a)

   Section 1915.92(a) provides:

   (a) All means of access and walkways leading to working areas as well as the
   working areas themselves shall be adequately illuminated.

   Compliance    Officer Nathaniel     Williams observed four instances where employees

were working with inadequate illumination:
Instance (a) -- An employee was working in an area where the temporary lights were
out. Ingalls’ supervisor Lulu Farmer told Williams that she had problems getting lights in
that area. Williams stated that the inadequate illumination created a tripping hazard due
to all of the debris and materials on the floor (Exh. C-41; Tr. 291-293).
Instance (b] -- Employees were required to perform deckwork in an area where light
bulbs had’burned out (Exh. C-42; Tr. 293-295).
Instance (cl -- Employees were working in an area where light bulbs were missing
from temporary lights (Tr. 295-296).
Instance cdl-- Employees in the locker shop were grinding hatchway doors. Six of
the room’s eight fluorescent lights were burned out (Tr. 297-298).
Ingalls raises the weak defense that Williams’ determination that the lighting was
inadequate was his subjective opinion. This defense is without merit. Williams documented
employees working in areas where light bulbs were burned out or missing. It is well within
his capabilities to determine whether or not the lighting was adequate. The standard by its
language contemplates that some level of personal judgment must be exercised when it
requires that working areas be “adequately illuminated.”
The Secretary has established a violation of 8 1915.92(a). Injuries resulting from
tripping over materials and debris due to inadequate illumination could be serious. A
penalty of $1,500.00 is appropriate.

                                             21
                                 Item 41: $ 1915.92(d)

   Section 1915.92(d) provides:

   (d) Where temporary lighting from sources outside the vessel is the only
   means of illumination, portable emergency lighting equipment shall be
   available to provide illumination for safe movement of employees.

   The ships at Ingalls’ shipyard are illuminated by temporary lighting from outside the

vessels. From time to time, the lights go out, leaving the employees in darkness. Later in
the construction process, battle lanterns were to be installed, but they were either not
installed or were not equipped with batteries at the time of Williams’ inspection (Tr. 98-99).
Williams believed that there was no other portable emergency lighting equipment.
Ingalls had flashlights available to its employees in its tool rooms on the ships
(Tr. 364-365). The Secretary does not consider flashlights to be “portable emergency
lighting equipment.” The standards do not define “portable emergency lighting equipment,”
and the Secretary offers no definition. Looking at the plain language of $ 1915.92(d), it
would appear that flashlights meet the requirements of the standard. Flashlights are
portable, they are lighting equipment, and they are frequently used in emergencies.’ The
Secretary argues that having the flashlights in the tool rooms takes them out of compliance
with the standard. Section 1915.92(d), however, requires only that the lighting equipment
be “available,” not that it be issued to each individual employee. The flashlights were
available to the employees within the meaning of the standard.
The Secretary has failed to established a violation of 5 1915.92(d). Item 41 will be
dismissed.

                Items 45a and 45b: $8 1915.181(b) and 1915.335(a)(l)(i)

   Section 1915.181(b) provides:

   (b) Before an employee is permitted to work on an electrical circuit, except
   when the circuit must remain energized for testing and adjusting, the circuit
   shall be deenergized and checked at the point at which the work is to be done
   to insure that it is actually deenergized.    When testing or adjusting an
   energized circuit a rubber mat, duck board, or other suitable insulation shall
   be used underfoot where an insulated deck does not exist.


                                           22
   Section 1915.335(a)(l)(i)     provides:

   (a)    Use of protective equipment.       (1)   Personal protective equipment.
   (i) Employees working in areas where there are potential electrical hazards                    .
   shall be provided with, and shall use, electrical protective equipment that is
   appropriate for the specific parts of the body to be protected and for the work
   to be performed.

   Williams conducted employee interviews in which he learned that the employees were

working on energized circuits without using personal protective equipment (Tr. 175-176).
Williams spoke with employees in the tool room who told him that protective equipment was
available if employees wanted to use it (Tr. 193). Joseph Krebs testified that protective
equipment is readily available to employees performing electrical work and that they could
check out any protective equipment they wanted from either the electrical tool room or the
main tool room (Tr. 359-360).
Unlike the standard cited in the previous item, the standards at issue here require
that the equipment in question actually be used; availability is not sufficient to meet the
requirements of the standard. Ingalls does not contend that its employees were provided
with and were required to use protective equipment.
The Secretary has established violations of $9 1915.181(b) and 1915.335(a)(l)(i). The
hazard created by the violations was electrical shock which could result in hospitalization
(Tr. 174, 178). The violations were serious. A total penalty of $3,500.00 is appropriate.

                       Docket No. 93-596: The Health Inspection

On August 5, 1992, OSHA Industrial Hygienist (now assistant area director for health) Jesse
Baynes began a health inspection of Ingalls’ worksite (Tr. 465-466). The inspection was in
response to a formal employee complaint filed with OSHA (Tr. 467). Baynes was
accompanied by OSHA Industrial Hygienist Denise Thomas. Baynes and Thomas held an
opening conference attended by several Ingalls’ representatives. Following the opening
conference, Baynes and Thomas commenced a walk-around inspection of the site
(Tr. 468-469).

                                                23
                     Citation No. 1: Alleged Serious Violations

                                Item 2: 6 1910.132(a\

   The Secretary    cited Ingalls for three instances of violating 0 1910.132(a), which

provides:

   (a) Application.       Protective equipment, including personal protective
   equipment for eyes, head, and extremities, protective clothing, respiratory
   devices, and protective shields and barriers, shall be provided, used, and
   maintained in a sanitary and reliable condition wherever it is necessary by
   reason of hazards of processes or environment, chemical hazards’ radiological
   hazards, or mechanical irritants encountered in a manner capable of causing
   injury or impairment in the function of any part of the body through
   absorption, inhalation or physical contact.

   Instance (a) of item 2 alleges:

   (a) Employees working with the transducers using a detergent as a lubricant,
   were not given adequate personal protective equipment (PPE). Appropriate
   PPE would prevent prolonged or repeated contact which MSDS indicates may
   cause skin irritations.

   Ingalls’ employees    used Wisk detergent        as a lubricant   in installing   transducers

(Tr. 472). Transducers, which weigh approximately 50 pounds, are underwater hydrophones
that are part of a ship’s sonar apparatus (Tr. 471, 812). The U. S. Navy specifies that soap
be used as a lubricant in installing the transducers. The employees dip their hands into the
detergent, wipe it on the transducer, and then pick it up to slide it into the grommets
(Tr. 812-814).
Baynes testified as to the result of this procedure (Tr. 472):

   And in doing so, what they were doing was coating their whole body, their
   upper body with the Wisk detergent.

   And this would be saturating their clothing, and it would be against their skin
   for [a] prolonged period of time, up to and including perhaps all day long,
   depending on the length of time that they were working with the product.

    Exhibit C-43 is a copy of the material safety data sheet (MSDS) for Wisk detergent.

Under “Symptoms of Overexposure,” the MSDS states:

                                             24
    EYE:           Irritation   from contact resulting in pain and possible cornea1
                   injury.

    SKIN:          Possible irritation from prolonged or repeated        contact.

    Section 8 of the MSDS provides information on special protection when using Wisk.

It states:

    Protective Gloves:
    Clean cotton gloves, if needed.

    Baynes testified (Tr. 475-476):

    At least a significant part of the time, they were wearing their normal street
    clothes. At other times, they would be wearing clothing that would be
    provided in the way of disposable clothing by Ingalls, but it would not be
    impervious clothing that would prevent the skin contact with the Wisk product.

    Sometime in 1991 or 1992, before the OSHA inspection that gave rise to this case,

Ingalls’ management learned that several of its employees had developed rashes
(Tr. 813, 825). Some employees filed grievances with their union because of the rashes they
developed (Tr. 591).
Krebs testified that Ingalls had used Wisk for over 30 years with no reported rashes
(Tr. 822). When employees developed rashes in 1991 or 1992, Ingalls was not sure what was
causing the rashes. It decided to wait until the next ship came up to see if those employees
working with Wisk also developed rashes (Tr. 823). (Transducer installation only takes place
during one and a half days per ship. In 1993, when Ingalls installed two ship sets, transducer
installation required a total of three days (Tr. 814).) When employees working with Wisk
on the next ship developed rashes, Ingalls required its employees to use gloves, boots and
raincoats when installing transducers (Tr. 824).
An employer is required to have available an MSDS for any hazardous substance to
which its employees are exposed. Ingalls had available the MSDS for Wisk, upon which it
could be expected to rely. All the MSDS recommended in the way of protective clothing
was cotton gloves. The Secretary makes it clear that he would have found the use of cotton

                                               25

gloves inadequate to meet the requirements of 5 1910.132(a). Baynes was adamant that
what was required was impervious clothing (Tr. 476).
In order to require an employer to go beyond the recommendation of the MSDS, the
Secretary must establish that the employer had reason to know that more stringent means
of protection was required. The Secretary has failed to do that here. He did not dispute
Ingalls’ contention that it had been using Wisk since 1960, with no reports of rashes
occurring until 1991 or 1992. While rashes were reported then, the Secretary failed to
adduce any evidence that should have alerted Ingalls to a cause and effect relationship
between the use of the Wisk and the rashes. When Ingalls determined that a causal
relationship did exist, it established a requirement for the use of protective clothing in
compliance with 5 1910.132(a). The Secretary has failed to prove that Ingalls had knowledge
of the hazardous condition to which the use of Wisk exposed its employees at the time of
the inspection. Instance (a) of item 2 will be dismissed.
Instance (b) of item 2 alleged:

     (b) Employees working with a fire cloth (Ami-Sil) were not given personal
     protective equipment to protect them from the dermatitis caused by the Arni-
      .
     Sll .

     Ami-Sil is a fiberglass-like material used as a fire cloth for wrapping various pieces

of equipment to protect the equipment from damage during installation in a ship. Without
the protective wrapping, slag burns, welding burns, and bumps would damage the equipment
(Tr. 477).
The MSDS for Ami-Sil describes the effects of overexposure: “Some AMI-SIL
characteristics are similar to fiber-glass which has been identified as a nuisance particulate
by ACGIH.” Under the section addressing special precautions, the MSDS states: “Any
person exhibiting sensitivity to glass fibers should avoid excessive contact w/skin”
(Exh. C-44).
Employees in the Land Based Test Facility (LBTF) rolled off pieces of Ami-Sil and
wrapped them around equipment which was then shipped to various locations around the
shipyard (Tr. 478). Baynes testified that he believed that Tngalls should have required its
employees to wear impervious gloves and clothing (Tr. 483).

                                                  26
   Charles Fayard was an electrician-welder        for Ingalls at the time of the OSHA

inspection (Tr. 713). He was assigned to work in the LBTF, wrapping Ami-Sil around
computer units (Tr. 714). Fayard was the only employee in LBTF who worked with Ami-Sil
a full 7 or 8 hours a day (Tr. 732). About the third week after he started working with
Ami-Sil, Fayard noticed blistering on his hands (Tr. 715). He reported the condition to his
supervisor who told him to go to the company hospital (Tr. 717). Fayard was then advised
to see his personal physician, who diagnosed Fayard as being allergic to Ami-Sil
(Tr. 719, 722).
Fayard knew that gloves were available in his department’s tool room upon request
(Tr. 733). He never requested any gloves and continued to work with the Ami-Sil for
approximately a month after he was diagnosed as being allergic to it (Tr. 734).
Ned Nonis was a combination electrician for Ingalls (Tr. 693). His first exposure to
Ami-Sil was in July 1992 when he lay down on top of computer banks wrapped in Ami-Sil
in order to install wave guides (Tr. 694). After about two hours, Nonis experienced a
sensation in his back like he was lying on top of metal shavings (Tr. 696). Nonis told his
supervisor, Tyrese Malone, about the irritation caused by the lying on the Ami-Sil. About
three days later, Nonis went to the company hospital and was told to see his personal
physician (Tr. 699-700). The rash persisted for six months after Nonis’s initial contact with
the Ami-Sil (Tr. 702). Nonis never asked for any type of protective equipment or clothing
when working around the Ami-Sil (Tr. 705, 710).
Harold Ward is Ingalls’ electronics supervisor in the LBTF area (Tr. 826). Ward
testified that protective clothing (coveralls and rubber gloves) was available in the tool room
(Tr. 828). Protective clothing for use with the Ami-Sil was optional, at the discretion of the
employees (Tr. 829). Ward stated that he received complaints from employees about rashes
during a two-week period. Charles Fayard was the first employee to complain (Tr. 830).
The Secretary contends that Ingalls had actual knowledge that exposure to Ami-Sil
was causing its employees to develop rashes. The MSDS for Ami-Sil warns only against
excessive contact with it for people “exhibiting sensitivity to glass fibers.” Under section VII,
“SPILL OR LEAK PROCEDURES,” the MSDS lists the following instructions (Exh. C-44):

                                           27
   Respiratory Protection (speci! type):
                                     No special requirements.                   Mouth and
   nose mask may be worn when cutting large quantities.

   Protective Gloves: Not required unless sensitive to fiber.

   Eye Protection:     Safety glasses may be worn but not required.

   Other Protective Equipment:        Normal wash-up after handling is recommended.

   The MSDS suggests to an employer                  that protective   clothing must be worn by

employees sensitive to the fibers in Ami-Sil. Employee complaints of rashes put Ingalls on
notice that certain of its employees should be required to wear protective clothing. It was
feasible to provide this clothing, which Ingalls, in fact, provided. Under the circumstances
where Ami-Sil was suspected of being the irritant, it was insufficient merely to refer
employees to their personal physicians without follow-up. Under these circumstances, there
was enough causal evidence to establish Ingalls’ constructive knowledge that Ami-Sil caused
the rashes. Fayard and Nonis testified that their personal physicians told them that they
were allergic to Ami-Sil and to avoid it. Yet neither one of them made use of the protective
clothing that they knew was readily available in the tool room. The employees should have
been more active in their own protection. However, the standard makes use of protective
equipment mandatory. It is the employer’s responsibility to require employees to wear
appropriate protective clothing. The conditions caused by the hazard included prolonged
irritation and rashes requiring a doctor’s treatment. The violation was serious. A penalty
of $600.00 is assessed.
As in instance (a), the Secretary has failed to establish that Ingalls had knowledge of
the hazardous condition. Based on the MSDS, Ingalls could assume that it was taking
adequate precautions.
Instance (c) of item 2 alleges:

   (c) Employees working with nofoul rubber were not given adequate personal
   protective equipment to protect them from the dermatitis caused by dust
   generated when grinding the rubber.

   Nofoul rubber is used by Ingalls to coat the sonar domes of its ships.                   Baynes

explained that “[t]he process consists of gluing the rubber to the surface of this sonar dome,

                                                28

and then the employees take hand grinders and grind the surface down to where it presents
a smooth, even, uninterrupted, if you will, surface across the sonar dome” (Tr. 485). The
grinding generates dust from the Nofoul rubber (Tr. 486).
Section V of the MSDS for Nofoul rubber lists the following acute health effects
(Exh. C-45):

   Excessive exposure to dust and/or fumes containing TBTO [tributyltin oxide,
   an ingredient of Nofoul rubber] will irritate the skin, eyes, upper and lower
   respiratory tract. Symptoms may include headache, nausea, vomiting, severe
   coughing, delayed (after shift) coughing spasms and shortness of breath may
   occur. Effects diminish or disappear within 12-36 hours after removal from
   exposure.

   Under section VI, “Worker Protection,” the MSDS states that employees exposed to

Nofoul rubber should wear respirators. Baynes acknowledged that Ingalls’ employees were
wearing respirators (Tr. 487). Under “SKIN,” section VI of the MSDS states: “Disposable
vinyl gauntlet gloves” (Exh. C-45).
Baynes testified that when he first observed Ingalls’ employees grinding the Nofoul
rubber, the employees were wearing “a cotton or a cotton-like jumpsuit” (Tr. 494). When
Baynes took air samples of the employees approximately 20 days later, the employees “were
being put into a disposable suit that covered the body, and they were taking gloves to their
hands and wearing the airline respirator” (Tr. 494).
When asked what protective clothing he believed Ingalls should have provided to its
employees working with Nofoul rubber, Baynes replied (Tr. 495):

   To protect them from the dermal source of entry, they should have something
   similar to the clothing that they ultimately went to, which would prevent the
   dust and the particles that they were grinding off and getting into their
   clothing and getting next to the skin and having the contact with the skin; a
   tieback type suit, something along that line.

   Baynes claimed that the department     supervisor, Rayford Tanner, showed Baynes a

rash that had developed on his chest and abdomen (Tr. 488). The Secretary introduced a
copy of a photograph into evidence that purported to be of Tanner’s rash (Exh. C-46).

                                          29

Tanner subsequently took the stand and denied having had a rash and denied that the
photograph was of him (Tr. 861-862).
The Secretary faces the same problem faced in instance (a). He is attempting to
require Ingalls to comply with a general standard by going beyond what the MSDS for a
substance requires. While some employees working with the Nofoul rubber did develop
rashes, the Secretary offered no proof as to a causal relationship between the Nofoul rubber
and the rashes. The MSDS lists numerous symptoms of overexposure to the rubber, but
development of a rash is not one of them. The MSDS recommends that gloves be worn
when working with the rubber, but is silent as to protective clothing.
The Secretary has failed to prove that Ingalls knew of a hazardous condition caused
by the Nofoul rubber. Instance 2 (c) will be dismissed.

                                Item 3: 5 1910.134(b)(6\

   Section 1910.134(b)(6) provides:

   (b) Requirements for a minimal acceptable program. (6) Respirators       shall be
   stored in a convenient, clean, and sanitary location.

   Baynes testified that the respirators used by the employees working with the Nofoul

rubber were stored in tool bags and lockers (Tr. 503). Exhibits C-47 and C-48 show a cloth
tool bag that was kept on the pontoon. The employees stored their respirators in the bag.
Baynes stated that storing the respirators with the tools would expose the respirators to
contamination (Tr. 504-505). Baynes also believed that storing the respirators in the tool
bags with other equipment exposed the face pieces to the possibility of becoming distorted
or misshapen, thus reducing the effectiveness of their fit (Tr. 506). Baynes testified that,
(Tr. 508-509):

   [T]he best way to store respirators is in individual compartments where the
   only thing you put in that compartment is the respirator. It would need to be
   of rigid shape to keep anything heavy from causing a distortion of the shape
   of the respirator face piece so it would give you a proper face piece to face
   seal.




                                             30
      Baynes also observed respirators stored in lockers in a trailer used by the rubber crew

(Tr. 624). Baynes believed that the lockers were not clean and sanitary because the
employees’ clothes and boots were also stored in the lockers with the respirators (Tr. 625).
Walter Williams, a shipfitter working in the sonar dome at the time of the OSHA
inspection, testified that he stored his respirator in a box in a cloth tool bag with his tools
(Tr. 799). Rayford Tanner, the supervisor of the rubber crew, testified that the respirators
were stored in lockers in work trailers along with tools used in the Nofoul operation
(Tr. 856).
Section 1910.134(b)(6) does not address the possibility of the respirator’s face piece
becoming distorted or misshapen. Therefore, Baynes’ concerns regarding distortion are
irrelevant. The standard does, however, require that respirators be stored in a “clean and
sanitary location.” Storage of respirators with tools used to work with Nofoul violates the
requirements of $$1910.134(b)(6). As noted in the previous section, excessive exposure to
dust or fumes containing TBO, an ingredient of Nofoul rubber, will irritate the skin, eyes,
and upper and lower respiratory tract. The possibility of contamination of the respirators
is high when they are stored in tool bags and lockers along with tools used with Nofoul
rubber.
The Secretary has established that Ingalls violated $ 1910.134(b)(6). The gravity of
the violation is moderate. A penalty of $2,000.00 is appropriate.

                               Item 4: 5 1910.134(d)(2)(iil

      Section 1910.134(d)(2)(ii) provides:

      (d) Air quality. (2) Breathing         air may be supplied to respirators    from
      cylinders or air compressors.

             (ii) The compressor for supplying air shall be equipped with
             necessary safety and standby devices. A breathing air-type
             compressor shall be used. Compressors shall be constructed
             and situated so as to avoid entry of contaminated air into the
             system and suitable in-line air purifying sorbent beds and filters
             installed to further assure breathing air quality. A receiver of
             sufficient capacity to enable the respirator wearer to escape
             from a contaminated atmosphere in event of compressor failure,


                                               31
              and alarms to indicate compressor failure and overheating shall
              be installed in the system. If an oil-lubricated compressor is
              used, it shall have a high temperature or carbon monoxide
              alarm, or both. If only a high-temperature alarm is used, the air
              from the compressor shall be frequently tested for carbon
              monoxide to insure that it meets the specifications in
              paragraph (d)(l) of this section.

    Ingalls was using an oil-lubricated       compressor   in the sonar dome area to supply

breathing air to the rubber crew (Tr. 511). The compressor was not equipped with either
a high-temperature alarm or a carbon monoxide alarm (Tr. 512, 870-871, 875).
The purpose of a high-temperature alarm is to alert employees that the compressor
is operating in a condition that could produce carbon monoxide in their breathing air. The
purpose of a carbon monoxide alarm is to alert employees that carbon monoxide is being
produced and that they need to remove themselves from that environment (Tr. 513-514).
Frank Spires is a facilities engineering specialist for Ingalls. He testified that the type
of air compressor Ingalls used is equipped with an automatic shutoff. The automatic shutoff
consists of two separate temperature cutoffs (Tr. 868). The technical manual for the
compressor states that “[a] temperature switch will shut down the compressor if the
discharge temperature reaches 240°F (115°C)” (Exh. R-31, p* 10). The temperature is in
relation to the lubricant that is used in the machine to maintain it below vapor points of all
the components of the compressor. The compressor shuts off before carbon monoxide
develops (Tr. 870). Spires claimed that in speaking with the manufacturers’ sales
representative and field people, he was unable to locate any compressor manufacturer that
makes a unit equipped with the alarms required by the standard (Tr. 877).
Ingalls contends that having an automatic shutdown device on a compressor is safer
than having an alarm on a compressor. The alarm is triggered after a problem with carbon
monoxide has already developed. The automatic shutdown device is activated before the
carbon monoxide problem reachs a critical stage (Tr. 872).
The Secretary has established a violation of 6 1910.134(d)(2)(ii). Ingalls is not free
to disregard the requirements of the standard because it believes that it implements a
superior method. Ingalls did not obtain a variance from the standard (Tr. 875). Ingalls has,

                                               32

however, established that its employees were exposed to minimal danger from its failure to
comply with the standard. The Secretary does not dispute Ingalls’ contention that the
compressor automatically shuts off before any carbon monoxide problem can develop.
Because the gravity of the violation is slight, the violation will be classified as “other” and
no penalty is assessed.

                                  Item 5: 5 1910.134(e)(S)

   Section 1910.134(e)(5) provides:

   (5) For safe use of any respirator it is essential that the user be properly
   instructed in its selection, use and maintenance. Both supervisors and workers
   shall be so instructed by competent persons. Training shall provide the men
   an opportunity to handle the respirator, have it fitted properly, test its face-
   piece-to-face seal, wear it in normal air for a long familiarity period, and,
   finally, to wear it in a test atmosphere.

   Baynes conducted interviews with employees in the sonar dome area and found that

several of the employees required to wear respirators had not been fit tested (Tr. 516).
Walter Williams, a shipfitter, testified that he was required to wear a respirator while
working in the sonar dome, but that he was not fit tested prior to its use (Tr. 797-798).
Herbert Lee, a chipper and grinder, also testified that he was not fit tested for a respirator,
although he was required to wear one while working in the sonar dome (Tr. 802-803). Mark
Cochran, a painter, testified that he was required to wear a respirator while painting, but
that he was not fit tested prior to its use (Tr. 790-791).
Ingalls argues that because of its large number of employees “some employees
inadvertently may be missed” (Ingalls’ brief, p. 44). This is not a viable defense. The safety
and health standard applies to each employee working for the employer.
The Secretarvd has established a violation of 8 1910.134(e)(5). The hazard created
by the violation is that of possibly exposing employees to toxic materials. Williams and Lee
were working with Nofoul rubber, Cochran was working around paint and solvent fumes.
The gravity of the violation is moderate. A penalty of $2,000.00 is assessed.

                                              33
                              Item 6: 5 1915.36(a)(2) and
                        Item 1 of Citation No. 2: 5 1915.36(a)(4)

   Item 6 and item 1 of Citation No. 2 (an alleged willful violation)        arose out of the

same fact situation. Therefore, they will be treated together. Sections 1915.36(a)(2) and (4)
provide:

    (a) In all cases when liquid solvents, paint and preservative removers, paints
   or vehicles, other than those covered by 6 1915.35(b), are capable of
   producing a flammable atmosphere under the conditions of use, the following
   precautions shall be taken:

              (2) Ventilation shall be provided in sufficient quantities to keep
              the concentration of vapors below ten (10) percent of their
              lower explosive limit. Frequent tests shall be made by a
              competent person to ascertain the concentration.

              (4) b,ly explosion proof lights, approved by the Underwriters’
              Laboratories for use in Class I, Group D atmospheres, or
              approved as permissible by the Mine Safety and Health
              Administration or the U.S. Coast Guard, shall be used.

   During Baynes’ inspection, an employee was spray painting in compartment              J-73-A

on LHD-3 (Tr. 524). The paint that the employee was using was White F-124, which has
a flash point of 100’ F. (Exh. C-52; Tr. 532). The compartment was ventilated with a
“sucker,” a 6-inch stainless steel piece of tubing with a fan on one side (Tr. 906-907). The
only source of illumination in the compartment was an Erickson light, which was not
explosion-proof (Tr. 558-559).
The painter was summoned to the deck above the compartment he was spray
painting, where Baynes and Ingalls’ industrial hygienist, Mark Frederic, and several others
were waiting. Baynes and Frederic spoke with the painter for 5 to 10 minutes (Tr. 539).
Baynes and Frederic disagree on the next sequence of events, but the discrepancy in
their testimony does not affect the outcome of this issue. According to Baynes, he and
Frederic descended the ladder to the compartment and stood at the foot of the ladder. He
took a reading of the atmosphere with an MSA Microguard Vapor Tester, which he had
calibrated that morning. The tester continuously displayed the lower explosive limit of the

                                             34

atmosphere. Baynes did not move more than a step or two from the ladder. The LCD
display on the tester read 11%, 1% above the percentage allowed by § 1915.36(a)(2). Upon
receiving that reading, Baynes showed it to Frederic and then they both exited the
compartment (Tr. 528-530, 652-656).
Frederic testified that he and Baynes went into the compartment twice. He stated
that he and Baynes moved around the compartment, away from the ladder, and took various
readings on the tester. Frederic recalled the first time they entered the compartment
(Tr. 914-915):

   When we went down the ladder, it was two to three percent at the ladder.
   We went about six or eight feet starboard again -- well, of course it was the
   first time -- and it was I think, six.

   And, then we came back to the ladder and it was eight.           As we were going
   back up the ladder, it was eight.

    Frederic drew a diagram of the compartment         (Exh. R-37) and commented        on the

readings Baynes took the second time they entered the compartment (Tr. 905):

   At the bottom of the ladder, it was two percent, six or eight feet, give or take
   a few, to the starboard was seven percent. Maybe about ten feet forward of
   the ladder, it was nine percent . . . And, in this extreme corner here
   [diagonally across from the ladder], it was eleven percent.

    Ingalls considers that Frederic’s version of events is significant because it believes that

the atmospheric reading for the compartment should be based on an average of the various
readings taken, which would produce a reading below 10% of the LEL. It is mistaken.
There is nothing in the standard that indicates that an average of readings should be taken,
or even that multiple readings need be taken. Both parties agree that a reading of 11% was
taken in some part of the compartment.
Ingalls argues that the cited standards are inapplicable because the White F-124 paint
being used is classified as a combustible, and not a flammable liquid (liquids whose flash
points are less than 100’ F are classified as flammable; liquids whose flash points are 100” F
or more are classified as combustible) (Tr. 929). Ingalls argues that because the White
F-1244 paint is a combustible liquid, it is not covered by @ 1915.36(a)(2) and (4), which

                                            35

refer to paint “capable of producing a flammable atmosphere.” There is nothing in the
standard that requires that the paint be a flammable liquid, only that it may produce a
flammable atmosphere. Ingalls’ argument is undermined by its own witness, Louis Janus,
whom Ingalls offered as an expert in chemistry (Tr. 926). During cross-examination this
exchange occurred (Tr. 936):

   Q ...      And, if a liquid had a flash point which did not render it a flammable
              liquid, per se, could such a liquid be capable of producing a flammable
              atmosphere under the conditions of use?

   A ...      Yes, they very well could.

   The Secretary has established that Ingalls failed to provide ventilation in sufficient

quantities to keep the LEL below 10%. It is undisputed that the painter was using an
Erickson light, which was not explosion-proof as required by the 8 1915.36(a)(4).
Ingalls’ only defense against this charge is that in January, 1988, one of its
representatives wrote a letter to OSHA to explain its position that the paint was not a
flammable liquid (Exh. R-42). Ingalls never received a response to this letter (Tr. 981).
Nevertheless, Ingalls claims that “[a]s a result of the correspondence, a citation was never
received.” (Ingalls’ Brief, p. 49). Therefore, Ingalls asserts it had reason to believe that
explosion-proof lights were not necessary. This argument is wholly rejected. Since OSHA
never responded to Ingalls’ letter, Ingalls had no basis whatsoever for asserting that a
citation was not issued “as a result” of the letter. The fact that a citation was not issued in
that case does not justify ignoring OSHA standards. The Secretary has established violations
of both $8 1915.36(a)(2) and (4). The hazard presented by the violations is that of fire or
explosion or both.
The violation of 0 191536(a)(4) was alleged as a willful violation.

           A willful violation is one committed with intentional, knowing or
   voluntary disregard for the requirements of the Act or with plain indifference
   to employee safety. . . It is differentiated from other types of violations by a
                              l




   “heightened awareness of the illegality of the conduct or conditions -- and by
   a state of mind -- conscious disregard or plain indifference.”




                                                 36

Calung Cop., 14 BNA OSHC 1789, 1791, 1990 CCH OSHD V 29,531 (No. 85-319, 1990)
(citation omitted).
Baynes explained why he believed Ingalls’ violation of 6 1915.36(a)(4) was willful
(Tr. 568):

     [Ingalls was] aware of the condition and had opted for or were aware that an
     option had been exercised to go to other than explosion-proof lights. That,
     to me, represented knowledge on their part of the hazardous condition and
     knowledge that it was a violation.

     What Baynes described, knowledge on the part of the employer that a standard is

being violated, is what is required to establish a serious violation of a standard. The
Secretary has failed to show a “heightened awareness” that would constitute a ‘willful
’violation. Item 1 of Citation No. 2 will be classified as serious. A penalty of $5,000.00 each
will be assessed for the violations of 8 1915.36(a)(2) and (4).

                                 Item 9a: 6 1915.99(g)(8)

     Section 1915.99(g)(8) provides:

     (g) Material safety data sheets. (8) The employer shall maintain copies of the
     required material safety data sheets for each hazardous chemical in the
     workplace, and shall ensure that they are readily accessible during each work
     shift to employees when they are in their work area(s).

     While at the Land Based Test Facility (LBTF), Baynes asked the foreman for a copy

of the MSDS for Ami-Sil. He was told that Earl Sanders, the tool room clerk, would get it
for him. Sanders gave Baynes an MSDS for lagging roll, not Ami-Sil. Sanders was unable
to find an MSDS for Arni-Sil and told Baynes that he would have to get one from the safety
department about half a mile away (Tr. 547).
The LBTF is a shop where employees wrap equipment with a protective covering
(Tr. 556, 828). As previously noted, the court in Dravo declined to expand the coverage of
the 8 1915 maritime standards to land based structural shops. Section 1915.99(g)((8) is
inapplicable to the LBTF.

                                             37
                                Item 9b: 5 1915.99(h)

   Section 1915.99(h) provides:

   (h) Employee infomzntion and training. Employers shall provided employees
   with information and training on hazardous chemicals in their work area at the
   time of their initial assignment, and whenever a new hazard is introduced into
   their work area.

   Item 9b cites two instances in which 0 1915.99(h) was allegedly violated.   Instance (b)

occurred at the LBTF where Ingalls failed to provide Charles Fayard with information and
training regarding the use of Ami-Sil (Tr. 551). Because it occurred at the LBTF, it is not
covered by the 5 1915 maritime standards.
Instance (a) occurred in the sonar dome. Supervisor Rayford Tanner admitted that
he did not provide his employees with information and training regarding dermatitis, which
may be caused by exposure to Nofoul rubber (Tr. 845).
The Secretary has established a violation with regard to instance (a) of item 9b. The
hazard presented by this violation is the development of dermatitis. The gravity is moderate.
A penalty of $500.00 is appropriate.

                     Citation No. 3: Alleged “Other” Violation

                               Item 1: 8 1910.1000(e)

   Section 1910.1000(e) provides:

   (e) To achieve compliance with paragraphs (a) through (d) of this section,
   administrative   or engineering controls must first be determined         and
   implemented whenever feasible. When such controls are not feasible to
   achieve full compliance, protective equipment or any other protective
   measures shall be used to keep the exposure of employees to air contaminants
   within the limits prescribed in this section. Any equipment and/or technical
   measures used for this purpose must be approved for each particular use by
   a competent industrial hygienist or other technically qualified person.
   Whenever respirators are used, their use shall comply with 1910.134.




                                          38
   Baynes sampled employees in the sonar dome for exposure to organic tin. One of

the employees, Ed Patterson, was found to be exposed over the permissible exposure limit
(PEL) (Tr. 573). “Tin, organic compounds” is listed in Table Z-1-A of 8 1910.1000. The
PEL for tin is .lmg/m3. The personal sample on Patterson was .428 mg/m3 (Exhs. C-55,
C-56; Tr. 579-580). Patterson was wearing protective clothing and an airline respirator,
which reduced his exposure to the tin (Tr. 576, 582).
Ingalls questions the accuracy of Patterson’s sample result. Another employee who
was sampled at the same time, John Love, had a sample result of only .099 mg/m3
(Tr. 639-640). However, a difference in the results of personal samples is not enough to
discredit their accuracy.
The Secretary has established a violation of 5 1910.1000(e). Because Patterson was
wearing protective clothing and a respirator, his exposure was minimal. No penalty is
assessed.

                        Docket No. 93497:   The Fatality Inspection

    On September        30, 1992, OSHA Compliance       Officer, Carmen Bunch began an

investigation of a fatality that occurred at Ingalls on September 28, 1992 (Tr. 998-999).
Bunch held an opening conference with representatives of Ingalls and then commenced his
investigation (Tr. 999). As a result of Bunch’s investigation, the Secretary issued a citation
to Ingalls on January 26, 1993, alleging serious violations of four of the 9 1910 standards
(Tr. 1000). At the time of the hearing, three items were still at issue.

                                      The Fatalitv

    On September 28, 1992, employee Patricia Dickerson was electrocuted          while using

an electric drill motor while on board a ship under construction. The fatality occurred when
the hot wire inside the drill motor’s handle came loose from its connection and contacted
the metal casing on the drill motor (Tr. 1096, 1098). The green grounding wire had
separated or broken within the cord itself, resulting in Dickerson becoming the ground
conduit at the time the hot wire contacted the metal casing (Tr. 1098).

                                            39
                                       Item 2: d 1910.305@)(92)(iii]

    Section 1910.305(g)(2)(iii) provides:

     (iii) Flexible cords shall be connected to devices and fittings so that strain
    relief is provided which will prevent pull from being directly transmitted to
    joints or terminal screws.

    As noted earlier in this decision (Docket No. 93-614, item 15), 8 1910.302(a)(2)

specifically excludes “installations in ships” from the coverage of 66 1910.302
through 1910.308. There is no dispute that the alleged violation took place aboard a ship
under construction. Therefore, 5 1910.305(g)(2)(“‘)
111 is inapplicable to the cited condition.
Item 2 will be dismissed.

                           Items 3a and 3b: 56 1910.334(a)[2)(i) and (ii)

    Sections 1910.334(a)(2)(i)            and (ii) provide:

    (2) Vifsualinspection. (i) Portable cord- and plug-connected equipment and
    flexible cord sets (extension cords) shall be visually inspected before use on
    any shift for external defects (such as loose parts, deformed and missing pins,
    or damage to outer jacket or insulation) and for evidence of possible internal
    damage (such as pinched or crushed outer jacket). Cord- and plug-connected
    equipment and flexible cord sets (extension cords) which remain connected
    once they are put in place and are not exposed to damage need not be
    visually inspected until they are relocated.
    (ii) If there is a defect or evidence of damage that might expose an employee
    to injury, the defective or damaged item shall be removed from service, and
    no employee may use it until repairs and tests necessary to render the
    equipment safe have been made.

    Section      1910.331 defines the scope of 8 1910.334(a)(2)(i)               and (ii).       Section

1910.331(c) provides:

    The provisions of $$ 1910.331 through 1910.335 do not apply to work
    performed by qualified persons on or directly associated with the following
    installations:

    i;i    l   Imtallutions in vehicles. Installations        in ships, watercraft . . . .




                                                     40
   “Qualified person” is defined in 8 1910.399 as “[o]ne familiar with the construction

and operation of the equipment and hazards involved. Dickerson was a first class electrician
(Tr. 1029). An electrician can be presumed to be familiar with the operation of an electric
drill motor and the hazards involved. Dickerson was a qualified person working on an
installation aboard a ship. Therefore, 8 1910.334 is inapplicable to the cited circumstances
as provided by 6 1910.331(c)(3).
Items 3a and 3b are dismissed.

             FINDINGS OF FACT AND CONCLUSIONS                     OF LAW

   The foregoing   decision constitutes the findings of fact and conclusions of law in

accordance with Federal Rule of Civil Procedure 52(a).

                                           ORDER

   It is hereby ORDERED        that the parties’ stipulations and joint motions and notice

of dismissal embodied in Exhibits J-l, J-2, and J-3 are incorporated by reference herein in
disposition of the relevant items. Based on the foregoing decision, the items of the citations
remaining in contest from Docket Nos. 93.614,93-596, and 93-597 are disposed of as follows:

Docket No. 93-614
Citation No. 1
Item Standard Disposition Penalty

    3a             8 1910.23(d)(l)(i)              Dismissed                      $ -00
    3b             5 1910.23(d)( l)(ii)            Dismissed                        a0a
    3c             5 1910.23(d)( l)(iii)           Dismissed
    3d             8 1910.23(d)( l)(iv)            Affirmed                          500O-.00
    15(a) - (i)    3 1910.303(g)(2)(i)             Dismissed                        l,i,.OO
                                                                                        0
    m     - (0     $ 1910.303(g)(2)(i)             Affirmed
    23             8 1910.425(c)(2)                Affirmed                        5,ooo.oo
    32             0 1915.72(a)( 1)                Affirmed                        3,500.oo
    W) & (d)       0 1915.73(c)                    Penalty only                    3,500.oo
    39(i) & (j)    8 1915.91(c)                    Dismissed
    39(k)          8 1915.91(c)                    Penalty only                      ;25
                                                                                      O- 00
    40             5 1915.92(a)                    Affirmed                         1,500~00
    41             8 1915.92(d)                    Dismissed                         a0a
    45a            8 1915.181(b)                   Affirmed                 1
    45b            8 1915.335(a)(l)(i)             Affirmed                 1      3,500.oo
                                                                  Total           $18,985.00


                                             41

Docket No. 93496
Citation No. 1
Item Standard Disposition Penalty

    2(a 2(c)      8 1910.132(a)                Dismissed               $     -o-
    209           0 1910.132(a)                Affirmed                      600.00
    3             $ 1910.134(b)(6)             Affirmed                    2,ooo.oo
    4             5 1910.134(d)(2)(ii)         Affirmed as “Other”            0
    5             8 1910.134(e)(5)             Affirmed                    2,boo.oo
    6             0 1915.36(a)(2)              Affirmed                    5,ooo.oo
    9a            5 1915.99(g)(8)              Dismissed                      O-
    9b            8 1915.99(h)                 Affirmed                      ioo .00

Citation No. 2
Item Standard Disposition Penalty

     1            0 1915.36(a)(4)              Affirmed as Serious     $ 5,ooo.oo

Citation No. 3

    Item                  Standard             Disposition                 Penalty

     1            8 1910.1000(e)               Affirmed                $ -00
                                                               Total   $15,100.00

Docket No. 93497
Citation No. 1
Item Standard Disposition Penalty

    2             5 1910.305(g)(2)(iii)        Dismissed
    3a            8 1910.334(a)(2)(i)          Dismissed
    3b            8 1910.334(a)(2)(i)          Dismissed




                                               NANCY J. SPIES
                                               Judge

Date: November 16, 1994

                                          42