OSHRC Commission decision Docket 87-0960 Decided May 24, 1990 Citations affirmed

Williams Enterprises, Inc.

Perimeter cable violation reinstated for $630

Apply this precedent to your situation

This is citable Commission precedent from 1990, and it may have been appealed since. Ezel checks how it stands today and answers your situation, with citations.

Currency note: this decision dates from 1990
The OSHA standards may have been amended, penalty amounts have been adjusted, and later Commission or court decisions may have changed the analysis since then. Treat this page as historical context, not current compliance advice. Verify the current standard before relying on any specific rule, threshold, or penalty mentioned here.
Decision of the Commission
This is a decision of the Occupational Safety and Health Review Commission, the highest level of agency review, citable as Commission precedent. It may have been appealed to a U.S. Court of Appeals after issuance; check subsequent history before relying on it. The full text below is from the official OSHRC release.
About this page: The plain-English summary and decision snapshot below were written by Ezel based on the official OSHRC release. The full text is the Commission's own document.
Read the official release (oshrc.gov)

Plain-English summary

Williams Enterprises performed structural steel erection on a Washington, D.C., building project. Employees came within one foot of two unguarded edges on a mostly decked second-tier floor, with fall distances of 20 to 30 feet. The ALJ vacated the perimeter-cable citation after concluding that installing the cable created a greater fall hazard, while separately affirming a crane-inspection-record item without a penalty. The D.C. Circuit reversed because Williams had neither pleaded nor proved the required elements of the greater hazard defense. Following the court's mandate, the Commission reinstated the serious perimeter-cable citation and assessed the Secretary's proposed $630 penalty.

Decision snapshot

  • Cited standard(s): 29 C.F.R. §§ 1926.750(b)(1)(iii) and 1926.550(b)(2)
  • Outcome: Serious perimeter-cable item affirmed with a $630 penalty; crane inspection-record item affirmed without a penalty.
  • Key point: An employer cannot obtain relief based on greater hazard without pleading the defense and proving all of its required elements.

Full text (OSHRC public release)

Docket No. 87-0960

SECRETARY OF LABOR,

Complainant,

v.

WILLIAMS ENTERPRISES, INC.,

Respondent

Docket No. 87-0960

ORDER

This case is here at the direction of the United States Court
of Appeals for the D.C. Circuit. Dole v. William Enterprises, Inc ., 876 F.2d 186
(D.C. Cir. 1989). rev'g William & Enterprises Inc. , 13 BNA OSHC 1868, 1988 CCH
OSHD � 28,255 (No. 87-960, 1988 ALJ) (unreviewed decision of Administrative Law Judge).
In accordance with the D.C. Circuit's decision and mandate, we hereby reinstate and affirm
the Secretary of Labor's citation 1 alleging that Williams committed a serious violation
of 29 C.F.R. � 1926.750(b)(1)(iii) by failing to install perimeter cable along two sides
of a temporary metal-decked floor on the second tier of a building in Washington, D.C.

Although the Administrative Law Judge determined that the cited
fall hazard existed and that Williams' employees were exposed to it, he vacated the
citation. The judge concluded that Williams' employees were exposed to "a greater
fall hazard" when installing the perimeter cable to abate the violation than when
performing their ordinary work and being exposed to the cited fall hazard.

The Secretary filed a petition for discretionary review with
the Commission, but the case was not directed for review.

The D.C. Circuit granted the Secretary's Petition for review
filed pursuant to section 11(b) of the Occupational Safety and Health Act of 1970
["the Act"], 29 U.S.C. � 660(b). Dole v. Williams Enterprises. Inc. , supra ,
876 F.2d at 191. The court concluded that, even though the judge's decision made no
reference whatsoever to the greater hazard defense, the judge had in effect vacated the
citation on the ground that Williams had established that defense. The court concluded
that the judge's decision was in error because Williams had not pleaded the greater hazard
defense in its answer (as required by the Commission's Rule of Procedure at 29 C.F.R. �
2200.36(b)), nor proven the three requisite elements of the defense: hazard of compliance
greater than hazard of noncompliance; alternative means of protection unavailable; and
variance unavailable or inappropriate. 876 F.2d at 188-190. According to the court,
"[w]ithout a showing on these elements of the claim, it was patently improper for the
Commission [judge] to vacate the Secretary's citation on the ground that abatement posed a
more serious hazard to Williams' employees." (footnote omitted) 876 F.2d at 190.
After acknowledging that "[t]he record clearly reflects that Williams violated �
1926.750(b)(1)(iii)," the court went on to determine that the violation was
"serious" under section 17(k) of the Act, 29 U.S.C. � 666(k), in that the
Secretary had proven that serious physical harm could result from the 20- to 30-foot fall
to which the employees were exposed. 876 F.2d at 191. According to the court, there was
"no other supportable conclusion from the record." Id. The court then remanded
the case to the Commission "with directions that [the citation at issue] be
reinstated." Id.

Having reinstated the citation pursuant to the D.C. Circuit's
instructions, we must consider what penalty to assess. The Secretary proposed a penalty of
$630 for the violation. Section 17(j) of the Act, 29 U.S.C. � 666(j), sets forth the
criteria to be used in assessing a penalty: size of employer, gravity of violation, good
faith of employer, and previous violations by employer. Based on those criteria, a penalty
of $630 is assessed for the citation.

Edwin G. Foulke, Jr.

Chairman

Velma Montoya

Commissioner

Donald G. Wiseman

Commissioner

Dated: May 24, 1990

ANN McLAUGHLIN, SECRETARY OF

LABOR,

U.S. DEPARTMENT OF LABOR

Complainant

v.

WILLIAMS ENTERPRISES,

INCORPORATED

Respondent

Docket No. 87-0960

APPEARANCES:

Mark D. Swartz, Esquire

U.S. Department of Labor

Office of the Solicitor

For the Complainant

James Brent Clarke, Jr., Esquire

For the Respondent

DECISION AND ORDER

TENNEY, Judge:

I. Introduction

On May 6 and 7, 1987, OSHA inspected a worksite of the
Respondent, Williams Enterprises, in Washington, D.C. As a result of that inspection
Respondent was cited for a "serious" violation of 29 C.F.R. 1926.750(b)(1)(iii)
alleging that it had failed to install wire rope railing around the perimeter of a
temporary metal-decked floor and for a violation of 29 C.F.R. 1926.550(b)(2) alleging that
monthly written inspection reports for a truck crane were not readily available.
Respondent filed a timely notice of contest.[[1]] After the filing of the Complaint and
Answer, the parties proceeded through discovery. A hearing was held on February 11, 1988.

II. Findings of Fact

  1. On May 6 and 7, 1987, Williams Enterprises, Incorporated, a
    corporation engaged in structural steel erection, had a workplace at the Intelstat project
    at 4000 Connecticut Avenue, N.W., Washington, D.C. Williams is an employer within the
    meaning of the Occupational Safety and Health Act. (Pleadings)

  2. Respondent's employees were welding on the second tier of
    the 90 feet by 90 feet octagonally shaped section of the Intelstat project designated as
    POD L. (Testimony of Wilfred Epps, Tr. 36; that of Darrell Moore, Tr. 78-79; that of
    Joseph Graham, Tr. 120-121; Joint Ex. 1, Gov. Ex. 3-A.)

  3. The metal decking on the second tier was substantially
    complete. Both Mr. Epps and Mr. Moore testified that the tier was 90% decked, Tr. 69, 93.
    Mr. Graham testified that decking was 75% complete, Tr. 117.) On the south and east sides
    of the second tier, decking was complete to the perimeter except for small triangular
    sections. (Testimony of Mr. Epps, Tr. 23, 24, 26; that of Mr. Moore, Tr. 93; that of Mr.
    Graham, Tr. 111, 125, 127, 128, 131, 140, 141, 145; Joint Ex. 2, Gov. Exs. 3A, 3B, 4A and
    4B.)

  4. Respondent's employees came within one foot of the edge of
    the floor when pulling up welding leads and when using a ladder to enter and exit the
    second tier. (Testimony of Mr. Epps, Tr. 30, 31, 38, 39, 66; that of Mr. Moore, Tr. 80-83;
    that of Mr. Graham, Tr. 126-127, 130, 157-158; Gov. Exs. 4A and 4B.) Pulling up welding
    lead required approximately 10 minutes a day. Using the ladder involved one to five
    minutes for each use. (Testimony of Mr. Moore, Tr. 81, 83.)

  5. There was no perimeter cable at the edges of the south and
    east sides of the second tier. (Testimony of Mr. Epps, Tr. 27, 38; that of Mr. Moore, Tr.
    86; that of Mr. Graham, Tr. 137-138.) The fall distance from the south side of the second
    tier was 20 feet to the mechanical room roof. From the east side, the fall distance was 30
    feet to the ground. (Testimony of Mr. Epps, Tr. 36, 37.)

  6. Respondent's employees were exposed to a fall hazard when
    pulling up welding lead and using the ladder. (Findings of Fact Nos. 4, 5, 6)

  7. Respondent's employees were exposed to a fall hazard when
    they installed cable on the south and east perimeters. (Testimony of Mr. Epps, Tr. 62.)
    Installing the cable on the south and east perimeters took three of Respondent's employees
    half an hour. In order to install the cable on the three undecked triangular corners,
    employees had to crawl or "coon" across four-to eight-inch wide steel beams,
    carrying cable that could weigh 150 pounds. (Testimony of Mr. Graham, Tr. 139-143.)

  8. Respondent's employees received a longer exposure to the
    fall hazard during installation of the guardrails than during the work that made the
    guardrails necessary. That part of the installation requiring Respondent's employees to
    "coon" across four- to eight-inch wide steel beams, exposed Respondent's
    employees to a more serious fall hazard than pulling up welding lead and using the ladder.
    (Findings of Fact Nos. 5, 6 and 7)

  9. A truck crane operated by Respondent was in use at the
    Intelstat workplace. (Stipulation, Tr. 98-99) On the dates of the inspection, May 6-7,
    1987, there were no monthly inspection records available for the crane. (Testimony of Mr.
    Epps, Tr. 99-100.)

  10. Respondent knew that the records were not available on the
    first day of the inspection but was not able to produce the records on the second day.
    (Testimony of Mr. Epps, Tr. 100; that of Charles Swann, Tr. 170-171.)

III. Discussion

1926.750(b)(1)(iii)

The cited standard reads as follows:

Section 1926.750 Flooring requirements

*
                 *
                 *

(b) Temporary flooring skeleton steel construction

in tiered buildings

(1)(iii) Floor periphery--safety railing. A safety railing of
1/2-inch wire rope or equal shall be installed, approximately 42 inches high, around the
periphery of all temporary-planked or temporary metal-decked floors of tier buildings and
other Multi-floored structures during structural steel assembly.

It is not disputed that for approximately 10 minutes each day
Respondent's employees came within one foot of an unguarded perimeter edge while pulling
up welding leads.[[2]] The Secretary alleges that this condition violates 29 C.F.R.
1926.750(b)(1)(iii). Respondent contends that the standard does not apply because the
metal-decked floor was not fully laid. The Secretary argues that the standard does not
require that metal decking completely cover the floor before it applies. She relies on The
Ashton Company, Inc ., 76 OSAHRC 76/B11, 3 BNA OSHC 1968, 1975-76 CCH OSHD � 20,351
(No. 5111, 1976).

Section 29 C.F.R. 1926.750(b)(1)(iii) was designed to prevent
persons from falling when working on otherwise unguarded floor perimeters. The Commission
has interpreted it to apply to temporary floors that were about three-fourths decked. The
Ashton Company . See Adams Steel Erection, Inc. , 87 OSAHRC / ,13 BNA OSHC 1073,
1080, 1986-87 CCH OSHD � 27,815, p. 36,406 (No. 77- 3804, 1987); Carr Erectors, Inc. ,
77 OSAHRC 14/C9, 4 BNA OSHC 2009, 1976-77 CCH OSHD � 21,471 (No. 7247, 1977).
Respondent's contention that similarities in the text of 29 C.F.R. 1926.750(b)(1)(iii) and
some provisions of ANSI A10.13, Safety Requirements for Steel Erection , point to an
interpretation that the standard applies only when temporary decking is fully laid, is
rejected. Respondent failed to establish any persuasive inference of a nexus between the
cited standard and the ANSI standard. The cited standard is an "established Federal
standard" adopted from rules issued under the Construction Safety Act. See 29 C.F.R.
1910.11 and 1910.12. Moreover, the Commission's interpretation is more consistent with the
Act's essential purpose of assuring safe and healthful working conditions for employees.

Although the standard applies to Respondent's workplace, entry of an abatement order
requiring the installation of perimeter cable would not provide Respondent's employees
with "appropriate" relief. 29 U.S.C. � 659(c). There is no persuasive evidence
that work was being done on the portion of the floor that was completed and was proximate
to the edge, except for pulling up the welding leads, which occurred without regard to the
progress in decking. Also, abatement would present Respondent with a "Catch 22"
dilemma. See U.S. Steel v. OSHRC , 537 F.2d 780, 783, 4 BNA OSHC 1424, 1425-26 (3rd
Cir. 1976). When installing the perimeter guarding, Respondent's employees received a
longer exposure to the fall hazard than pulling up welding lead had required. See H. S.
Holtze Construction v. Marshall , 627 F.2d 149, 151-152, 8 BNA OSHC 1785, 1788 (8th
Cir. 1980). The employees also were exposed to a greater fall hazard than they ordinarily
encounter, that of falling from a four- to eight-inch wide steel beam.

In any future situations that may arise, the Secretary may wish
to consider applying a requirement for personal protective equipment in order to afford
employees fall protection.

1 926.550(b)(2)

The cited standard, 29 C.F.R. � 1926.550(b)(2) reads as
follows:

1926.550 Cranes and derricks

*
             *
             *

(b) Crawler, locomotive and truck cranes

*
             *
             *

(2) All crawler, truck, or locomotive cranes in use shall meet the applicable requirements
for design, inspection, construction, testing, maintenance and operation as prescribed in
the ANSI B30.5-1968 Safety Code for Crawler, Locomotive and Truck Cranes.

Section 5-2.1.5 of ANSI B30.5 provides:

5-2.1.5 Inspection Records

Written dated and signed inspection reports and records shall
be made monthly on critical items in use such as brakes, crane hooks, and ropes. Records
shall be kept where readily available.

The evidence establishes that the records were not readily
available. The compliance officer requested the records from Respondent's crane operator
and one of Respondent's safety representatives on May 6, 1987, the first day of the
inspection, but they did not produce them. The compliance officer gave Respondent an
opportunity to produce the records on the next day, but they were not made available.

Conclusions of Law

  1. Section 29 C.F.R. 1926.750(b)(1)(iii) applies to temporary
    floors in steel erection that are not fully decked.

  2. The Secretary of Labor has failed to demonstrate that entry
    of an abatement order requiring the installation of wire rope around the perimeter of the
    second level at POD L of Respondent's worksite would be appropriate.

  3. Citation 1, item 1, which alleged a serious violation of 29
    C.F.R. and proposed a penalty of $630, is vacated.

  4. The Secretary has sustained the burden of proving that the
    Respondent failed to make crane inspection records readily available, and that the
    employer knew the records were not readily available.

  5. The Respondent has violated section 5-2.1.5 of ANSI
    830.5-1968, Safety Code for Crawler, Locomotive and Truck Cranes as adopted by 29 C.F.R.
    1926.550(b)(2). No penalty for the violation was proposed, and none is assessed.

SO ORDERED

PAUL A. TENNEY

Judge, OSHRC

MAY 31 1988

Dated: Washington, D.C.

FOOTNOTES:

[[1]] Williams withdrew its notice of contest to two other
items.

[[2]] Because exposures to unguarded perimeters that occur when
employees use steps, ramps or ladders are not the type of exposure for which guarding is
generally required, see 29 C.F.R. 1926.500(d)(1), the exposures involving the ladder would
not require guarding.