🧪 TEST MODE ACTIVE Use test card: 4242 4242 4242 4242
OSHRC Commission decision Docket 09-0625 Decided July 30, 2010 Settled

LandCoast Insulation, Inc.

Settlement approved after scaffold-collapse case

Apply this precedent to your situation

This is citable Commission precedent from 2010, and it may have been appealed since. Ezel checks how it stands today and answers your situation, with citations.

Currency note: this decision dates from 2010
The OSHA standards may have been amended, penalty amounts have been adjusted, and later Commission or court decisions may have changed the analysis since then. Treat this page as historical context, not current compliance advice. Verify the current standard before relying on any specific rule, threshold, or penalty mentioned here.
Decision of the Commission
This is a decision of the Occupational Safety and Health Review Commission, the highest level of agency review, citable as Commission precedent. It may have been appealed to a U.S. Court of Appeals after issuance; check subsequent history before relying on it. The full text below is from the official OSHRC release.
About this page: The plain-English summary and decision snapshot below were written by Ezel based on the official OSHRC release. The full text is the Commission's own document.
Read the official release (oshrc.gov)

Plain-English summary

The case arose after a 165-foot scaffold collapsed inside a boiler, killing one LandCoast employee and injuring several others. The judge had affirmed serious violations concerning scaffold-component training and the use of preliminary engineering drawings and unapproved component substitutions, while another scaffold item was withdrawn. After review was directed, LandCoast withdrew its review petition and the parties filed a settlement resolving all remaining issues. The Commission approved and incorporated the settlement, ended further review, and set aside the judge's decision to the extent it conflicted with the settlement. The Commission order does not state the settlement's detailed citation or penalty terms.

Decision snapshot

  • Cited standard(s): 29 C.F.R. § 1926.451(f)(4); 29 C.F.R. § 1926.454(b); 29 U.S.C. § 654(a)(1)
  • Outcome: Settlement approved and the ALJ decision set aside to the extent inconsistent with the agreement.
  • Key point: An approved Commission settlement controls over inconsistent portions of the underlying judge's decision.

Full text (OSHRC public release)

Landcoast insulation, Inc., Docket No. 09-0625

SECRETARY OF LABOR,

Complainant,

v.

OSHRC Docket No. 09-0625

Landcoast insulation, inc.,

Respondent.

ORDER

This case is before the Commission on a Direction for Review entered by Commissioner
Horace A. Thompson III on June 14, 2010. On July 6, 2010, Respondent filed a Notice
To Withdraw Petition For Discretionary Review. Shortly thereafter, on July 8, 2010, the
parties filed a Stipulation and Settlement Agreement (“Settlement”) pursuant to
Commission Rule 100(c), 29 C.F.R. § 2200.100(c), which disposes of all remaining
issues. We hereby approve the Settlement and thus no further review by the Commission
is warranted.

We incorporate the Settlement into this Order and we set aside the Administrative Law
Judge’s Decision and Order to the extent that it is inconsistent with the Settlement.

SO ORDERED.

/s____

Thomasina V. Rogers

Chairman

/s____

Horace A. Thompson III

Commissioner

/s____

Cynthia L. Attwood

Dated:   July 30, 2010                                        Commissioner

Secretary of Labor,

Complainant

v.

OSHRC Docket No. 09-0625

LandCoast Insulation, Inc.,

Respondent.

Appearances:

Uche N. Egemonye, Esquire, Office of the Solicitor, U.S. Department of Labor, Atlanta, Georgia

For Complainant

David C. Goff, Esquire, Deutsch, Kerrigan & Stiles, LLC, Gulfport, Mississippi

For Respondent

Before: Administrative Law Judge Ken S. Welsch

DECISION AND ORDER

LandCoast Insulation, Inc. (LCI) is an industrial specialty contractor with an
office in New Iberia, Louisiana. On November 4, 2008, LCI was installing a system
scaffold, approximately 165 feet high, inside a boiler at Mississippi Power, Plant Daniel,
in Moss Point, Mississippi when the scaffold collapsed. One LCI employee died and
several employees were injured. The Occupational Safety and Health Administration
(OSHA) inspected the collapse and issued to LCI serious and willful citations on March
24, 2009. LCI timely contested the citations.

The serious citation alleges LCI violated 29 C.F.R. § 1926.451(f)(4) (item 1) for
failing to immediately repair, replace, or remove from service the damaged scaffold
components, and 29 C.F.R. § 1926.454(b) (item 2) for failing to adequately train by a
competent person each employee to recognize hazards associated with damaged scaffold
components. The serious citation proposes a penalty of $4,500.00 for each alleged
violation.

The willful citation alleges LCI violated § 5(a)(1) of the Occupational Safety and
Health Act of 1970 (Act), 29 U.S.C. § 651 et seq ., for erecting a scaffold without using
critical components listed on the scaffold drawings prepared by an engineering company,
or in the alternative, as amended by the Secretary on November 2, 2009, for using
scaffold drawings that were not approved by a registered professional engineer (PE) and
were marked “PRELIMINARY Not for Construction.” The willful citation proposes a
penalty of $63,000.00.

The hearing was held on November 9 and 10, 2009, in Biloxi, Mississippi. The
parties stipulated jurisdiction and coverage. The Secretary withdrew Citation no. 1, item
1, alleged violation of § 1926.451(f)(4). The parties have filed post hearing briefs.

LCI denies the alleged violations. LCI argues that there is no evidence damaged
scaffold components were used on the scaffold inside the boiler. LCI claims it relied
upon the scaffold drawings from Patent Construction Systems (Patent) and the scaffold
components supplied by Patent to ensure the scaffold was properly erected. Also, LCI
asserts unpreventable employee misconduct as to the alleged training violation.

For the reasons discussed, Citation no. 1, item 2 and Citation no. 2, item 1, are
affirmed as serious and total penalties of $8,000.00 are assessed.

BACKGROUND

LCI is an industrial specialty contractor which started in business in 1973. LCI’s
CEO is Robert M. Morton, son of the company’s founder. LCI employs approximately
800 employees. As a specialty contractor, LCI installs scaffolds, insulation, paint, fire
proofing, industrial coatings, and performs heat, electric or steam tracings. Scaffolding is
approximately 65 percent of LCI’s business (Tr. 285, 287, 332).

In 2008, PIC Group, Inc. (PIC), a service provider, contracted LCI to, among
other things, erect the scaffold inside a boiler at Mississippi Power, Plant Daniel, in Moss
Point, Mississippi. PIC was responsible for changing the high temperature water tubes in
the boiler during the plant outage. LCI’s project superintendent was Donald Sullivan.
The shift supervisors were brothers, Carlos and Alfonso Galvan, who were also the
designated competent persons for erecting the scaffold. LCI utilized approximately 50
scaffold builders and helpers on the project (Tr. 26, 47, 303, 326, 333).

Prior to erecting the scaffold, LCI contracted Patent to provide the engineering
drawings for the scaffold system inside the boiler because the scaffold was designed to be
higher than 125 feet above the base. Patent was also contracted to supply the scaffold
components (Tr. 334-335).

On August 19, 2008, Patent provided LCI with an initial set of scaffold drawings.
On September 26, 2008, Patent prepared a second set of scaffold drawings, consisting of
seven sheets. These drawings were given to superintendent Sullivan who gave copies to
Mississippi Power and PIC. On each sheet of the second set of drawings, there was a
copy of the PE’s seal and the words, in bold print, “PRELIMINARY Not for
Construction.” The seal was not signed or dated by the PE. The drawings also called for
the use of approximately 210 plate trusses including 14 of the plate trusses to be used at
levels 14 and 16, where the vertical posts could not be continuous to the ground. At
these levels, the posts had to be relocated to fit around the “bull nose” inside the boiler
(Exhs. C-2, R-3, Tr. 58, 118, 279, 312).

On October 13, 2008, pursuant to its contract, Patent began delivering scaffold
components to the project. According to Patent’s shipping invoice, 115, 8-foot heavy
horizontals “substituted for the 8-foot plate truss” were among shipped components. On
October 16, the invoice shows that 59, 8-foot plate trusses were shipped to the project
(Exhs. C-4, R-6).

Thereafter, LCI began erecting the scaffold. At levels 14 and 16, day shift
supervisor Carlos Galvan used heavy horizontals instead of the plate trusses in relocating
the vertical posts around the “bull nose.” By using the heavy horizontals, Galvan had to
install the bracing in a different configuration, above the heavy horizontal as opposed to
underneath the plate truss (Exh. C-4).

On November 4, 2009, at approximately 5:40 a.m., the scaffold inside the boiler
collapsed. The scaffold was approximately 165 feet above the scaffold base. After the
collapse, the scaffold components were removed from the boiler and placed in the “lay
down yard” (Tr. 27, 37, 103).

OSHA compliance safety and health officer Henry Rust initiated an inspection
into the scaffold collapse at approximately 4:00 p.m., on November 4, 2009. His
inspection took several days and involved interviewing employees and taking
photographs. Rust was unable to identify the cause of the collapse (Tr. 28-29, 47, 110).

As a result of OSHA’s inspection, LCI received the serious and willful citations at
issue.

DISCUSSION

The Alleged Violations

In order to establish a violation of an occupational safety or
health standard, the Secretary has the burden of proving:
(a) the applicability of the cited standard, (b) the
employer’s noncompliance with the standard’s terms, (c)
employee access to the violative conditions, and (d) the
employer’s actual or constructive knowledge of the
violation ( i.e., the employer either knew or, with the
exercise of reasonable diligence could have known, of the
violative conditions).

Atlantic Battery Co., 16 BNA OSHC 2131, 2138 (No. 90-1747, 1994).

There is no dispute the scaffold erected inside the boiler was a “system scaffold”
(Tr. 300, 302) . A “system scaffold” is defined as “a scaffold consisting of posts with
fixed connection points that accept runners, beams, and diagonals that can be fixed
connected at predetermined levels” ( § 1926.450(b), Definitions ) .

Serious Citation No. 1

Alleged Violation of § 1926.454(b)(Item 2 )

The citation alleges that “[O]n or about November 4, 2008, at Mississippi Power
Plant Daniel in Moss Point, MS, employees were not sufficiently trained to a level of
proficiency to recognize hazards such as damaged scaffold components.” Section
1926.454(b)(1) provides:

The employer shall have each employee who is involved in
erecting, disassembling, moving, operating, repairing,
maintaining, or inspecting a scaffold trained by a
competent person to recognize any hazards associated with
the work in question. The training shall include the
following topics as applicable:

The topics for such training include the nature of scaffold hazards, the correct
procedures for erecting and disassembling the type of scaffold in question, the design
criteria for the scaffold, the maximum intended load-carrying capacity and intended use
of the scaffold, and any other pertinent requirements of Subpart L.

Although an employer is free to train by any method, the training must be
modeled on the applicable OSHA requirement and “specific enough to advise employees
of the hazards associated with their work and the ways to avoid them.” El Paso Crane
and Rigging Co ., 16 BNA OSHC 1419, 1425 nn 6 & 7 (No. 90-1106, 1993). The
instruction must be more than “vague advice.” Anderson Excavating and Wrecking Co.,
17 BNA OSHC 1890, 1892 (No. 92-3684, 1997).

The Secretary alleges that LCI did not train employees to recognize the hazard
associated with using damaged components. Section 1926.451(f)(4) requires the immediate
repair, replacement, adequate bracing, or removal of any part of a scaffold damaged or
weakened. Employees, therefore, need training on hazards associated with damaged scaffold
components.

Although the standard does not define what constitutes a damaged component, it
defines a weakened component, pursuant to 29 C.F.R. 1946.451(a), as:

. . . each scaffold and scaffold component shall be capable of
supporting, without failure, its own weight and at least 4 times
the maximum intended load applied or transmitted to it.

No testing was performed to determine whether any scaffold component fell below the
4:1 standard. The Secretary has withdrawn the allegation of LCI using damaged components
(citation no. 1, item 1- alleged violation of § 1926.451(f)(4)).

According to the Secretary, damaged components included bent, broken, pitted,
rusted, or corroded components. Such components were photographed by Rust in the “lay
down yard” after the collapse (Exh. C-1; Tr. 87 ). He testified that Sullivan and Carlos Galvan
agreed that the components shown in the photographs should not have been used to erect the
scaffold in the boiler (Tr. 45, 47).

A determination of whether damaged components were used in erecting the scaffold in
this case is not required. The issue before the court is whether “each” employee was trained
by a competent person in the recognition and avoidance of damaged components. The
standard at issue places the responsibility to train “each” employee on the employer.

To show LCI’s lack of training, the Secretary offered the testimony of two former
employees and friends, Matthew Krause and Michael Burkes (Tr. 201). Krause and Burkes
worked two shifts for LCI at Plant Daniel before the scaffold collapse and were told not to
come back unless called by LCI.

Matthew Krause testified that LCI hired him as a scaffold builder at the end of
October 2008. His duties consisted of “passing up materials and helping put the bracing on,
helping put the planking together, and building the scaffold to the immediate top up there to
where they needed to work off of the scaffold and the boiler” (Tr. 193). He testified that LCI
did not train him to recognize the hazards associated with damaged scaffold components. He
said LCI’s orientation consisted of “where to go, where not to go, stay out of the areas with
red tape, stay out of the enclosed areas, confined spaces, and more or less just staying in the
area where LandCoast employees were working in the boiler room and outside the boiler
room” (Tr. 194). During the only tool box meeting he attended, he was instructed to “watch
our pinch points, and make sure we were tied off, 100 percent tied off safety-wise” (Tr. 196).
Krause said he spoke with Carlos and Alfonso Galvan to no avail about damaged scaffold
components which he described as “the parts were rusted, the tubing was damaged, the lock
pins were no good, boards were split, boards were cracked, some of the planks were damaged
and everything else” (Tr. 195).

Michael Burkes corroborated Krause’s testimony regarding the lack of training on the
hazards associated with damaged scaffold components. Burkes testified that LCI hired him as
a helper around November 1, 2008. LCI then assigned him to build scaffolds. He testified
that he received no training related to scaffold hazards. He was not trained how to identify
and discard scaffold components that were bent, cracked, corroded, or otherwise damaged
(Tr. 203-204). When he left the project, the scaffold was more than 100 feet high, “almost to
the top” (Tr. 207).

CEO Morton testified that scaffold builders carry a card certifying their qualifications
from LCI or other scaffold company. Based on the card, scaffold builders are presumed to be
trained when hired (Tr. 319-320). According to Morton, the employees involved in erecting
scaffolds would just know which parts to discard. He testified:

Oh, yes. Well, it’s going to be whether the supervisor or the
actual guys erecting scaffold, you’re going to know. I mean,
when you go to stab a leg or something and that thing is bent or
you’ve got rings that are bent on it, then it’s coming back down.
You know, it can’t be used. (Tr. 300-301).

Superintendent Sullivan testified that LCI had a policy regarding discarding damaged
scaffold components. The components would be inspected, and if damaged, would be set
aside and not used (Exh. R-22, p. 33). He testified that there were daily toolbox meetings and
supervisors communicated this policy to employees (Exh. R-22, p. 14). Section
1926.451(f)(3) requires that scaffolds and scaffold components are inspected for visible
defects by the competent person before each work shift.

Although LCI has an extensive training programs including written safety policies,
employees’ safety handbook, daily toolbox meetings, and a safety officer on site, its training
program was shown lacking on instructing each employee on the hazards associated with
damaged scaffold components and the means to avoid the hazards. Despite LCI’s reliance
upon the scaffold builders to carry a card and competent persons to discard damaged
components, the standard requires training to “each” employee on the recognition and
avoidance of the hazards associated with damaged components. The employees need
instruction on, among other things, what constitutes a damaged component, the reason(s) the
damaged components should not be used, and if a damaged component is found, what action
to take.

Morton’s testimony that employees are “going to know” is not the training
contemplated by the standard (Tr. 300, 302). It was not shown that LCI had a policy to train
employees on not using damaged components. No record that such instruction was given
during an LCI training program or toolbox meeting was offered and no supervisor or
instructor testified to providing such training to the employees. Although they worked only
two days, the testimony of Krause and Burkes establish LCI’s lack of training on the general
hazards associated with scaffolds including damaged components.

LCI’s violation of § 1926.454(b) for inadequate training is established by the record.
Even though the scaffold components were provided by Patent and scaffold builders carried
cards, the responsibility remained with LCI to train each of its employees in recognizing and
avoiding the hazards associated with damaged components.

Serious Classification

LCI’s violation of § 1926.454(b) was properly classified as serious. A “serious”
violation under § 17(k) of the Act is established if there is a substantial probability of death or
serious physical harm that could result from the cited condition and the employer knew or
should have known with the exercise reasonable diligence of the presence of the violation.

In this case, LCI knew the training requirements. Section 21, paragraph 5 of LCI’s
“Safety Policies and Procedures” entitled “Scaffolds and Ladders” addresses scaffold training
to include fall hazards, fall protection, electrical hazards, safe handling, load-carrying
capacities, and “any other pertinent requirements” (Exh. R-15). Scaffolds constitute in excess
of 60 percent of LCI’s business (Tr. 332). Although this is a training violation, if a scaffold
accident occurred such as in this case, the likely result would clearly be serious injury or
death. See Miniature Nut and Screw Corp. , 17 BNA OSHC 1557, 1558 (No. 93-2535, 1996)
(the occurrence of an accident does not have to be the substantial probable result of the
violative condition but, rather, that a serious injury is the likely result should an accident
occur).

Unpreventable Employee Misconduct

As an affirmative defense, an employer, in order to establish “unpreventable employee
misconduct,” must show that it has (1) established work rules designed to prevent the
violation, (2) adequately communicated these rules to its employees, (3) taken steps to
discover violations, and (4) effectively enforced the rules when violations are discovered.
American Sterilizer Co ., 18 BNA OSHC 1082, 1087 (No. 91-2494, 1997).

LCI argues that several safety policies and procedures were in place to prevent the
lack of training and it has a written disciplinary program to ensure compliance (Exhs. R-12
thru R-16). The safety rules were given to each employee and safety toolbox meetings were
held at the beginning each shift (Exhs R-17 thru R-20).

Despite LCI’s written safety program, LCI’s unpreventable employee misconduct
defense is rejected. LCI failed to identify the employee(s) it alleges caused the misconduct,
specify the safety rule(s) the employee(s) allegedly violated, the alleged communication
provided to the employee(s) on the rule and the discipline administrated showing enforcement
of the safety rule(s). LCI merely identified general policies and procedures including a rule
mandating that all employees be trained. The written rule, however, does not specifically
identify training on the hazards associated with damaged components. Sullivan testified that
he discussed the training policy with Carlos Galvan and asked him “to pass it on” (Exh R-22,
p. 33). He did not see Galvan providing the instruction and no record was offered showing
the training occurred. Also, LCI failed to show enforcement of its disciplinary policy. There
was no evidence that LCI disciplined employees for violating the training rule and, in fact,
there was no showing an employee at Plant Daniel was disciplined as a result of the scaffold
collapse.

Willful Citation No. 2

Alleged Violation of § 5(a)(1) of the Act ( Item 1 )

The citation, as amended, alleges that “[O]n or about November 4, 2008 at Mississippi
Power, Plant Daniel in Moss Point, MS, scaffold had been erected over 125 feet above the
base without using the critical components listed on the prints that were designed by a
registered professional engineer” or in the alternative, “using scaffold plans that were marked
PRELIMINARY NOT FOR CONSTRUCTION. One feasible and useful abatement method
to correct this hazard was to follow the prints as designed by a registered professional
engineer.”

Preliminary Issues

1. Judicial Estoppel

LCI claims the Secretary’s alternative allegations are inconsistent and confusing
because on one hand, she claims the scaffold drawings were preliminary and should not have
been used by LCI to erect the scaffold, and, on the other hand, she claims LCI should have
followed the drawings by using only plate trusses. LCI argues judicial estoppel precludes the
inconsistent positions taken by the Secretary. “Absent any good explanation, a party should
not be allowed to gain an advantage by litigation on one theory, and then seek an inconsistent
advantage by pursuing an incompatible theory.” 18 Federal Practice and Procedure, 4477, p.
782 (Wright, Miller & Cooper, 2002). Also see, New Hampshire v Maine , 121 S.Ct. 1808
(2001) (judicial estoppel is invoked where “intentional self-contradiction is being used as a
means of obtaining unfair advantage”).

As discussed in New Hampshire v Maine , judicial estoppel is an equitable doctrine
invoked in the court’s discretion. The doctrine protects the integrity of the judicial process
from clear, inconsistent positions in different forums. Judicial estoppel generally applies
when a party who has won a judgment on one ground takes a contradictory position in a
subsequent litigation in an effort to obtain a second judgment.

This case involves a single action under the Act where the Secretary has asserted two
alternative theories for the violation of §5(a)(1), the general duty clause. The Commission has
long recognized the Secretary’s authority to plead in the alternative, particularly in alleged §
5(a)(1) violations. See Commission Rule 2200.30(e); Paschen Contractors, Inc. , 14 BNA
OSHC 1754, 1757 (No. 84-1285, 1990). Also, the two legal theories asserted by the Secretary
are not contradictory, i.e., LCI should not have used the drawings because they were marked
“PRELIMINARY Not for Construction,” and if it did use the drawings, LCI should not have
deviated from their specifications.

LCI’s judicial estoppel argument is rejected.

2. Mohammad Ayub’s Testimony

LCI argues that Mohammad Ayub’s testimony, as an expert witness, should be
stricken because the State of Mississippi requires an individual practicing engineering in the
State of Mississippi to be licensed by the state (Miss. Code Ann. 73-13-3). Mr. Ayub is a
federal employee with the Directorate of Construction, U.S. Department of Labor,
Washington, D.C. He is a certified PE registered in the States of Maryland and Virginia, as
well as, a registered structural engineer in the State of California (Tr. 345).

According to LCI, the state’s definition of the “practice of engineering” includes
giving expert testimony. There is no dispute that Mr. Ayub is not a licensed PE in the State of
Mississippi and that he had not received permission by the Mississippi Board of Licensure to
testify.

The Act is a federal law and this OSHA proceeding, pursuant to the Act, is governed
by federal law and not the laws of a state. Mr. Ayub was not practicing engineering in the
State of Mississippi. He was in the State of Mississippi only to testify in this OSHA
proceeding.

LCI’s argument regarding striking Mr. Ayub’s testimony is rejected.

Section 5(a)(1) Violation

Section 5(a)(1) of the Act provides:

Each employer -

shall furnish to each of his employees employment and place of
employment which are free from recognized hazards that are
causing or likely to cause death or serious physical harm to his
employees.

To establish a violation of § 5(a)(1), the Secretary must show that (1) there was an
activity or condition in the employer's workplace that constituted a hazard to employees, (2)
either the employer or its industry recognized that the condition or activity was hazardous, (3)
the hazard was causing or likely to cause death or serious physical harm, and (4) there were
feasible means to eliminate the hazard or materially reduce it. Waldon Healthcare Center , 16
BNA OSHC 1052, 1058 (No. 89-2804, 1993).

  1. The Hazard

A “hazard” is defined in terms of conditions or practices deemed unsafe over which an
employer can reasonably be expected to exercise control. Morrison-Knudson Co./Yonkers
Contacting Co . , A Joint Venture, 16 BNA OSHC 1105, 1121-1122 (No. 88-572, 1993).

The hazard in this case is identified as using preliminary drawings to erect the scaffold
without approval by a PE and not following the drawings when substituting scaffold
components. Such conditions are deemed hazardous because there is no assurance that proper
load calculations had been performed to ensure the stability of the scaffold or the suitability of
the substituted component.                             The scaffold drawings utilized by LCI to erect
the scaffold were prepared by Patent. Although the drawings contained Patent’s preprinted
PE’s name and copy of his seal, the drawings were not shown to be final because the drawings
were not signed or dated by the PE and each sheet contained in bold designation
“ PRELIMINARY Not for Construction.”

Also, substituting heavy horizontals for the plate trusses shown in the scaffold
drawings is a hazard. LCI acknowledges that a heavy horizontal has a lesser strength capacity
than a plate truss (Tr. 274). Patent’s scaffold drawings called for 14, 8-foot plate trusses at
scaffold levels 14 and level 16 because the vertical posts were no longer continuous to the
ground (Tr. 58-59, 280). The posts had to be relocated to fit around what was referred to as
the “bull nose” in the boiler. Also, the scaffold drawings showed the bracing placed below
the plate trusses. Instead, LCI had to place the bracing above the heavy horizontals because
of the configuration of the hoizontals (Tr. 256-258). LCI’s expert, PE Allen Palmer conceded
that the plate trusses to be used on levels 14 and 16 were “in more critical locations because
of the weight distribution” (Tr. 282).

Although Patent’s shipping invoice shows that heavy horizontals were substituted for
some of the plate trusses, the scaffold drawings were not modified to reflect the substitution
and no information was provided by Patent to show where the heavy horizontals could be
utilized instead of the plate trusses. A substitution shown in a shipping invoice does not
amend or modify the scaffold drawings. There was no evidence Patent’s PE approved the
substitution.

LCI’s argument that there was no hazard created by the substitution of heavy
horizontals is rejected. PE Palmer’s testimony that the heavy horizontals with additional
bracing accomplished the same goal as the plate trusses was not based upon appropriate
calculations for such opinion (Tr. 260). Also, the hazard is deviating from drawings not
approved by the PE, and not whether, by chance or accident, the substitution provided levels
14 and 16 with the same strength capacity.

The lack of calculations by the Secretary regarding the structural integrity of the
scaffold system as built by LCI does not show a lack of a hazard. “[T]here is no requirement
that there be a ‘significant risk’ of the hazard coming to fruition, only that if the hazardous
event occurs, it would create a ‘significant risk’ to employees.” Waldon Healthcare Center ,
16 BNA OSHC at 1060. The hazard was using scaffold drawings, not finalized by a PE, and
making a substitution not approved by a PE.

As the scaffold contractor, it was LCI’s responsibility to erect the scaffold in
accordance with final drawings certified by a PE. A PE was used by LCI to prepare scaffold
drawings for a scaffold system more than 125 feet high because “as you get higher . . . there’s
more weight to the scaffold system, and it requires a professional engineer to design that to
make sure that the scaffold has the strength to withstand the load” (Tr. 55).

The hazard of utilizing “Preliminary” scaffold drawings and not complying with the
drawings is established.

  1. The Hazard was Recognized

A hazard is deemed “recognized” when the potential danger of a condition or activity
is either actually known to the particular employer or generally known in the industry
Pepperidge Farm Inc ., 17 BNA OSHC 1993, 2003 (No. 89-0265, 1997) .

Using scaffold drawings not approved by a PE and carrying the “preliminary”
designation to erect a system scaffold 165 feet in height is recognized as a hazard by the
construction industry as well as by LCI. Under ANSI/ASSE A10.8-2001. “Safety
Requirements for Scaffolding- section 9.13, states in part; “System scaffolds erected higher
than 125 feet above the adjustable base shall be designed by a qualified registered
professional engineer . . . ” (Exh. C-3). PE Mohammed Ayub, OSHA’s Director of the Office
of Engineering, testified that in erecting a scaffold based on drawings, it was:

The industry practice is that if they get a drawing at a site that
has a notation in bold, “not for construction” everything freezes.
Everything has to stop in its tracks, and they have to wait until
they get a new drawing which does not have that title, “not for
construction.” So, “not for construction,” regardless of the fact
that it has a stamp or not, whether it is signed or not, whether it
is dated or not, “not for construction” is a directive to the
contractor not to use that drawing for the construction. Period.
That is an industry practice. (Tr. 354-355).

LCI’s expert, Alan Palmer, a PE licensed in the State of Mississippi, agrees that at a
minium, there was a contradiction on the face of the drawings. He testified that “ . . . you do
not want to have that wording ‘not for construction’ on the drawings you are using” (Tr. 268).
At the minimum, he agreed that the drawings presented LCI with “conflicting information”
which should have been resolved before erecting the scaffold (Tr. 245, 268). It should have
been clarified by the designer of the scaffold before LCI began erecting the scaffold. CEO
Morton recognized the role of the PE when he testified that the drawings are only final if
“they say it’s good” (Tr. 318).

Shift Supervisor Carlos Galvan, who had previously worked for Patent, knew the
difference between preliminary drawings and final drawings (Exh. C-4). He knew the
drawings needed to be signed, dated, and certified by the PE. He stated that for the drawings
to be used for construction, a PE had to date and put his signature on the drawings. He
recognized the importance of following drawings approved by a PE. “[The drawings] are
required for the safety of the people working on [scaffolds;] OSHA requires it” (Exh. C-4).

Substituting components not shown on scaffold drawings is also a recognized hazard
by the industry and LCI. PE Ayub testified the construction industry practice mandates that
only the PE, who designed the scaffold, could make substitutions of components. He
explained “that is a very complex issue because a truss has a different load carrying capacity,
much larger than a heavy [horizontal]. And, no one should make the decision for the
substitution [except] by the engineer who had designed the scaffold” (Tr. 357). The
substitution of components in Patent’s shipping invoice was not shown to be approved by the
PE and does not alter or modify scaffold drawings.

Patent’s PE Ken Chevis, whose copied seal is on the scaffold drawings, testified; “you
come up with a final design, you seal it, and you deliver it to the site. If a substitution
happens, then that request would be given back to the engineer, and then the drawings would
have to be modified to distinguish where he wants the substitutions. Need to know where in
the plans to make the substitution, not just that it is a substitution” (Tr. 179). Patent’s
designer Charles Knight, who prepared the preliminary scaffold drawings, described the
shipping invoices as “a preliminary list, so if any substitutions had been made, that would
have come to my attention; and, then, therefore, through the regularly submitted drawings for
engineering approval, the changes would have been made for the allowable substitutions to be
made. Now, that something not to take lightly” (Tr. 158).                Utilizing scaffold
drawings not approved by the PE and substituting heavy horizontals for trusses shown on
scaffold drawing is a recognized hazard. The confusion and contradictions in the drawings
and invoices as acknowledged by Palmer should have been clarified with Patent before
erecting the scaffold.

  1. Likelihood of Serious Injury

The criterion is not the likelihood of an accident or injury, but whether, if an accident
occurs, would the results likely cause death or serious injury. Waldon Healthcare Center , 16
BNA OSHC at 1060.

The recognized hazard of erecting a scaffold system in excess of 165 feet high with
preliminary scaffold drawings not approved by a PE and substituting components not shown
on the drawings could result in serious injuries to employees from a scaffold collapse or
struck by falling components, if an accident occurred (Tr. 56). The death of an LCI employee
and the serious injury to other employees are evidence of the hazard associated with a scaffold
erection. Kelly Springfield Tire Co. , 10 BNA OSHC 1970, 1973-1974 (No. 78-4555, 1982),
aff’d 729 F.2d 317 (5 th Cir. 1984) (an accident may demonstrate that a condition presents a
hazard to an employee). LCI does not dispute the likelihood of death or injury.

  1. Feasible Abatement

As the final element in establishing a § 5(a)(1) violation, the Secretary must show that
the proposed abatement of the recognized hazard will “eliminate or materially reduce the
hazard.” Cardinal Operating Company, 11 BNA OSHC 1675, 1677 (No. 80-1500, 1983).
The Secretary’s identified abatement measure need not be shown to have prevented the
accident.

In this case, the Secretary’s abatement measures involve erecting the scaffold based on
final drawings approved by the scaffold designer and the employer should adhere to the
drawings, not substituting components, unless approved by the scaffold designer. LCI does
not dispute the feasibility of the abatement measures.

LCI’s § 5(a)(1) violation is established.

Willful Classification

LCI’s violation of § 5(a)(1) of the Act is classified as willful. A willful violation is
one committed with intentional, knowing or voluntary disregard for the requirements of the
Act, or with plain indifference to employee safety. Continental Roof Systems, Inc ., 18 BNA
OSHC 1070, 1071 (No. 95-1716, 1997). A willful classification is more than a showing that
an employer was aware of the conduct or conditions constituting the alleged violation. There
must be a showing of “heightened awareness.” Also, “[T]he Secretary has a more stringent
and more difficult burden of proof to show willfulness where the employer is charged with a
violation of section 5(a)(1) . . . . A more concrete evidentiary showing is required.” Ho , 20
BNA OSHC 1361, 1378 (Nos. 98-1645, 98-1646, 2003), aff’d, 401 F.3d 355 (5 th Cir. 2005).

Although LCI’s knowledge of the recognized hazard is established, the record fails to
show that LCI acted with heightened awareness that a hazardous condition existed and that
employee safety was at risk due to the hazardous condition. LCI contracted Patent to design
the scaffold system because it wanted a PE to design and make load calculations on a scaffold
in excess of 125 feet in height. Project manager Sullivan denied being told the drawings were
preliminary when he received them from Patent (Exh. R-22, p. 25; Tr. 77). Patent had already
provided LCI with an initial set of scaffold drawings which did not contain a PE’s seal (Exh.
R-3).

The second set of drawings given to Sullivan contained the PE’s seal. Sullivan
testified that he did not see the PRELIMINARY Not for Construction” on the drawings. He
also gave copies of the drawings to PIC and Mississippi Power who did not advise LCI not to
use the drawings. Mississippi Power gave LCI the “go-ahead” to start construction of the
scaffold after receiving the drawings and periodically inspected the scaffold at various levels
during erection (Tr. 312, 334). LCI had worked with Patent on prior scaffold projects.

LCI’s expert Allen Palmer, a PE licensed in the State of Mississippi, testified that “the
presence of the seal there indicates that the drawings have been reviewed in this case by Mr.
Chevis” (Tr. 244). He testified that in the State of Mississippi, construction drawings should
never be released with an engineer’s seal unless those drawings were reviewed by the
engineer (Tr. 245-246, 251-252).                    On the substitution of components, LCI relied
upon Patent to ship the proper components. Patent’s shipping invoice showed the heavy
horizontals were substituted for plate trusses. Such substitution by Patent could infer to LCI
approval by the PE. Also, the record indicates the horizontals were installed in conformity
with industry practice. PE Palmer testified the horizontals with bracing provided the same
strength and stability capabilities as the trusses.

Although LCI should have resolved the contradictions on the scaffold drawings and
shipping invoices before erecting the scaffold, such failures do not rise to the level of intent or
plain indifference to employee safety. The scaffold drawings contained the PE’s seal and his
name. It was the second set of drawings Patent had prepared. Patent made the substitution to
heavy horizontals which LCI could have assumed was approved by the PE. Scaffolding
accounts for over 60 percent of LCI’s business.

A serious violation of § 5(a)(1) is established.

Penalty Consideration

In determining an appropriate penalty, consideration of the size of the employer’s
business, history of the employer’s previous violations, the employer’s good faith, and the
gravity of the violation is required. Gravity is the principal factor.

LCI is not entitled to credit for size because it employs approximately 800 employees
(Tr. 78, 332). LCI is entitled to credit for history and good faith because there is no evidence
LCI received prior serious citations within the proceeding three years. Also, LCI has a
written safety program, daily toolbox meetings and a project safety manager on site (Exhs. R-11 thru R-21).

A penalty of $1,000.00 is reasonable for LCI’s serious violation of § 1926.454(b)
(Citation 1, Item 2). As admitted by Morton, LCI relied upon the scaffold builders to just
know which damaged components to remove and not utilize. Such reliance does not equate to
the training of “each” employee as contemplated by the standard. Although LCI has a
training program including tool box meetings, such training was inadequate. There was no
showing that employees were trained to recognize and avoid the hazards associated with
damaged scaffold components.

A penalty of $7,000.00 is reasonable for LCI’s serious violation of § 5(a)(1) of the Act
(Citation 2, Item 1). The use of drawings not approved by a scaffold designer and using
components contrary to the scaffold drawings are contrary to good construction practices.
Fifty LCI employees were exposed to the hazard.

FINDINGS OF FACT AND

CONCLUSIONS OF LAW

The foregoing decision constitutes the findings of fact and conclusions of law in
accordance with Rule 52(a) of the Federal Rules of Civil Procedure.

ORDER

Based upon the foregoing decision, it is ORDERED:

Serious Citation No. 1

Item 1, serious violation of § 1926.451(f)(4), is withdrawn by the Secretary.

Item 2, serious violation of § 1926.454(b), is affirmed and a penalty of $1,000.00 is
assessed.

Willful Citation No. 2

Item 1, willful violation of § 5(a)(1), is affirmed as serious and a penalty of $7,000.00
is assessed.

__/s/Ken S. Welsch____

KEN S. WELSCH

Judge

Date:      May 5, 2010

Get today's answer for your situation

You just read Commission precedent from 2010. Ezel checks whether it still stands, including any court review since, and answers your specific situation, with citations.

Opens in Ezel Pro. Every answer cites the authority it relies on.